Back to search

Aristotle University Of Thessaloniki (AUTH)

Η συμβολή των ωτοακουστικών εκπομπών στην αντικειμενική ακουολογική μελέτη ασθενών με εμβοές

Abstract

dc:description

Otoacoustic emissions (OAEs) are sounds generated from the normal cochlea and are obtained from a properly sealed external ear canal, with a specially designed device. Experimental and clinical studies have shown that OAE generation is due to the micromechanical properties of the outer hair cells, which determine the linear and non-linear mechanical properties of the cochlea. Spontaneous otoacoustic emissions are generated by the functional outer hair cells, in the absence of an evoking acoustic signal, while evoked otoacoustic emissions (TEOAEs-DPOAEs) are generated from the normal cochlea, after sound stimulation. Experimental and clinical studies have demonstrated the characteristic properties, the acquisition and analysis parameters and the factors that influence the amplitude of OAEs or prevent OAE recording. Cochlear hearing loss, as a result of outer hair cell dysfunction or destruction, is the most important pathologic factor in the recording of abnormally reduced DPOAEs. DPOAE amplitude has an opposite relationship with hearing threshold. Hearing threshold elevation over 20 dB reduces the DPOAE amplitude. DPOAE are not recordable when hearing threshold exceeds 40 dB. Thus abnormal reduction of the DPOAE amplitude gives objective information on the presence of a cochlear dysfunction. It was shown that subclinical outer hair cell disorders, not manifested clinically and not detected by pure tone audiometry, result in the reduction or absence of DPOAEs. Tinnitus is a result of several causal factors and disorders, involving the auditory system, mainly the middle and inner ear. It is postulated that the cochlea is the most common site of subjective tinnitus, as a result of outer hair cell dysfunction or destruction, from noise exposure, degeneration processes of aging, ototoxic agents and metabolic factors. SOAEs were initially considered as an objective tool to measure subjective tinnitus. Experimental and clinical studies have shown that SOAEs appear in a small proportion of tinnitus patients and have no clinical value. Their presence gives strong evidence of cochlear normalcy, but their absence is not an indication of cochlear malfunction. The interest focused in the study of tinnitus with evoked OAE measurements which are clinically valuable in the detection of cochlear dysfunction. DPOAEs, as frequency specific, are recently used in the audiological assessment of patients with tinnitus. Recent studies of tinnitus patients with DPOAEs documented that they are abnormal, or not detectable, in the frequency region of tinnitus, even among persons with clinically normal audiogram. DPOAEs were consistently reduced among tinnitus patients, within the high frequency region. The aim of the study was to evaluate the clinical utility of DPOAEs in the objective measurement of tinnitus, by testing a great number of patients with tinnitus and normal hearing and patients with mild to moderate sensorineural hearing loss. We studied 1) the influence of tinnitus on the appearance of SOAEs and DPOAEs in 150 patients with tinnitus and normal hearing and 2) the combined influence of tinnitus and hearing loss on the appearance of SOAEs and DPOAEs in 160 patients with tinnitus and mild to moderate cochlear hearing loss. According to the audiogram configuration we have separated the patients into the category of high frequency hearing loss, which included 75 patients and into the category of acoustic trauma (notched-like) hearing loss, which included 85 patients, in order to examine the influence of the type of hearing loss in the appearance of SOAEs and DPOAEs, 3) the influence of aging on DPOAE amplitude. Thus, we separated the patients into two groups, under 50 years and over 50 years of age. We compared the amplitude of DPOAEs, obtained from the right and left- tinnitus and non tinnitus- ears, in both age groups of patients with tinnitus and hearing loss and of patients with tinnitus and normal hearing, with the amplitude of DPOAEs obtained from normal ears without tinnitus (control group). The findings of our study were the following: SOAE are more frequent in normal hearing ears with tinnitus (17,6 %) than non tinnitus ears (12.5%). SOAEs are more frequent in women than men and in the right than left ear. Stable and reproducible, single and multiple SOAEs appeared at all frequencies, mostly at frequencies over 1500 Hz. SOAEs appeared in a small proportion (6,3 %) of the hearing-impaired ears, at frequencies with normal hearing threshold. DPOAE amplitude was abnormally reduced or not detectable at all frequencies with elevated hearing threshold, over 30 dB, in ears with high frequency hearing loss and notched-like hearing loss. DPOAEs were recorded with abnormally reduced amplitude, in the majority of normal hearing patients with tinnitus (80%) than in non tinnitus normal hearing persons. The difference in DPOAE amplitude was statistically significant at all frequencies between patients 50 years of age. No statistically significant differences were noticed with the DPOAE amplitude between the right and left ears. Reduction of DPOAE amplitude showing a tendency to abnormality was noticed in the non tinnitus ear of patients with unilateral tinnitus, compared with non tinnitus ears of persons without tinnitus. In conclusion, DPOAE amplitude measurements offer objective information on the integrity and function of the cochlea in normal hearing patients with tinnitus. The sizable proportion of abnormal DPOAEs, found in the study of tinnitus patients with pure-tone hearing thresholds within clinically normal limits, strongly indicates that tinnitus is due to subclinical cochlear dysfunction. This finding has important diagnostic implications since, for the majority of normal hearing patients with tinnitus, it is possible to document abnormal cochlear function in a frequency region corresponding to their perceived tinnitus. Age- related changes in DPOAE amplitude were noticed in the study, documenting the effect of aging on cochlear function.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Ψηφίδης, Δημοσθένης
  • Psifidis, Dimosthenis

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/23782

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Ψηφίδης, Δημοσθένης; Psifidis, Dimosthenis. Η συμβολή των ωτοακουστικών εκπομπών στην αντικειμενική ακουολογική μελέτη ασθενών με εμβοές. Aristotle University Of Thessaloniki (AUTH), 2009. http://hdl.handle.net/10442/hedi/23782