Back to search

National and Kapodistrian University of Athens

Μελέτη της τμηματικής μυοκαρδιακής λειτουργικότητας και της ινότροπης εφεδρείας σε ασθενείς με αμφικοιλιακό βηματοδότη με τη χρήση ιστικού doppler κατά τη διάρκεια της ηχωκαρδιογραφίας φόρτισης με δοβουταμίνη

Abstract

dc:description

AIM Biventricular pacing (BivP) is an established modality for heart failure treatment. Aim of the study was to assess the acute and long term (1 year) effects of BiVP on total and regional longitudinal LV function using conventional echocardiographic indices and tissue Doppler imaging (TDI) derived deformation parameters. Additionally we investigated the relationship between the dynamic performance of regional LV deformation following ldDob and the acute and chronic effects of Bivp. METHODS Thirty five (35) consecutive patients (mean age 64±9 years, 25 males-10 females) with moderate to severe chronic heart failure [NYHA III (30) or IV (5), left ventricular (LV) ejection fraction (EF) 27±7%] due to dilated (20) or ischemic (15) cardiomyopathy, who underwent BivP, were prospectively included in the study. All patients were studied after the implantation of BivP and a year later on. The echocardiographic study was performed before (BivP-) and after (BivP+) the activation of pacemaker at rest (R) and at low dose dobutamine (ldDOB) (10μg/kg/min), using a commercially available ultrasound system (VIVID 7). The follow up study was performed at R and ldDOB during BivP status only. Left ventricular end-diastolic (EDVLV) and end-systolic (ESVLV) volumes (cm3) were estimated (Simpson’s rule) as well as the respective ejection fraction EF (%). Using TDI, longitudinal velocities (Vel:cm/sec), time to peak velocities (T),strain (SI:%) and strain rate (SR: 1/sec) were measured at basal (B), mid (M) and apical(Ap) regions of septal (S) and lateral (LAT) wall from the four chamber apical view RESULTS All patients completed the echocardiographic protocol without complications. During the 1 year follow up 4 patients had died and the remained 31 underwent echocardiographic examination at rest and post ldDOB. BivP+ induced acute decrease in both left ventricular volumes and increase in EF compared to BivP- (EDVLV: 249±114 vs. 268±116 cm3, p<0.001, ESVLV: 173±98 vs. 198±97 cm3, p<0.001 and EF: 32±9 vs. 27±7% p<0.01). While on BivP+, dobutamine induced further decrease in both ventricular volumes and a respective increase in EF (EDVLV: 232±96 vs. 249±114 cm3, p<0.001, ESVLV: 155±75 vs. 173±98 cm3, p<0.001, EF: 35±9 v 32±9, p<0.01). One year later, the beneficial effects of BivP remained at rest (EDVLV: 229±116 vs 268±116 cm 3, p <0.001, ESVLV:157±96 vs 198±97 cm3, p<0.001 and EF: 34±8 vs 27±7% p<0.01). There was significant shortening of QRS duration after BivP+ compared with BivP- (141±29 vs. 174±34 msec, p<0.001). The application of BivP acutely reduced the lateral-septal time delay (TD) mainly in the mid and apical levels compared to the basal one with no changes in the timing of peak systolic velocities at the respective septal levels. The dysynchrony (dys) further improved after the administration of ldDob while a year later the better synchronization between septal and lateral wall still remained. BivP improved regional strain in the apical segment of septum, whereas it improved in all 3 segments of the lateral wall. The basal lateral segment showed the greater increase during BivP. Dobutamine increased further the strain only at the apical lateral segment. During follow up the improvement of S and SR in M and Ap Septum and in the whole lateral wall remained (p<0.01). ................................................................................................................................

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Papadopoulos, Konstantinos
  • Παπαδόπουλος, Κωνσταντίνος

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/24013

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Papadopoulos, Konstantinos; Παπαδόπουλος, Κωνσταντίνος. Μελέτη της τμηματικής μυοκαρδιακής λειτουργικότητας και της ινότροπης εφεδρείας σε ασθενείς με αμφικοιλιακό βηματοδότη με τη χρήση ιστικού doppler κατά τη διάρκεια της ηχωκαρδιογραφίας φόρτισης με δοβουταμίνη. National and Kapodistrian University of Athens, 2008. http://hdl.handle.net/10442/hedi/24013