National and Kapodistrian University of Athens
Ποσοτική ανάλυση της μορφολογίας του κύματος Τ για τη διαστρωμάτωση του βραχυπρόθεσμου αρρυθμικού κινδύνου σε ασθενείς με οξύ έμφραγμα του μυοκαρδίου
Abstract
dc:descriptionBackground: Risk stratification of post-myocardial infarction (MI) patients is a particularly relevant clinical issue, especially in the era of device cardiology, which requires special measures in order to target interventions and allocate efficiently the available resources. The heterogeneity of repolarization of the ventricular myocardium has been shown to be related to mechanisms of ventricular arrhythmias. The spatial QRS-T angle (QRSTA) is a measure of the deviation between the main QRS and T vectors calculated from the net QRS and T wave areas, which reflects the variations of the shape and durations of actions potentials throughout the ventricular myocardium, i.e. the spatial repolarization heterogeneity. It has been shown, in healthy subjects, that this angle exhibits a circadian variation, being higher during the morning hours and lower during the night. We studied prospectively the potential prognostic significance of certain quantitative descriptors of repolarization (in particular the spatial QRSTA and its circadian variation) in a post-MI cohort. Methods: A 24-hour, 12-lead ambulatory digital electrocardiographic (ECG) recording (SEER MC, GE Marquette) was obtained, before hospital discharge, in 199 consecutive MI patients (age 63.4±9.1, 137 males), who were admitted to the University Cardiology Department of Hippokration Hospital, in Athens. Eligible patients were those with an admission and discharge diagnosis of either ST-elevation, or non-ST-elevation MI. The QRS and T wave areas in predetermined orthogonal XYZ leads were derived from the 12-lead QRS and T wave areas using the transfer coefficients of Edenbrandt and Pahlm, following which, the QRSTA was computed as an angle between the maximal spatial QRS and T vectors. In each patient, the medians of the values recorded in each 10-second ECG for three hours during daytime (08.00 to 11.00h) and night time (00.00 to 03.00h) were computed for heart rate, QT, QTc and QRSTA. Patients were followed-up for a year after the index MI. The composite endpoint of the study included cardiac death and/or sustained life-threatening arrhythmia (ventricular tachycardia or ventricular fibrillation) during the first year after the index MI. Results: The event rate of the composite endpoint was 10.4% during the one-year follow-up. The median QRSTA in patients who met the endpoint was 125.1ο, significantly different form those who did not (84.3o, p=0.001). Patients with QRSTA higher than 109o had a 21% chance to meet the endpoint during the one-year follow-up, as opposed to 3.3% in patients with QRSTA lower than 109o (odds ratio 7.82, 95% confidence interval 2.1-29.1, p=0.001). The negative predictive value of the test was about 97%. In the multivariate analysis, after including a battery of potential confounding factors, QRSTA remained significant (p=0.025). The Cox regression analysis showed that a 10o-increase in QRSTA conferred a 20% increase in risk. As far as its circadian variation was concerned, QRSTA showed higher values during the day: average QRSTA values in day- and night-time were 90? and 86? (p=0.0049), respectively. ...............
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Giannopoulos, Georgios
- Γιαννόπουλος, Γεώργιος
Subjects
dc:subject × 20- Έμφραγμα μυοκαρδίου
- Διαστρωμάτωση κινδύνου
- Κοιλιακή επαναπόλωση
- Ηλεκτροκαρδιογραφία
- Holter ρυθμού
- Κιρκάδια διακύμανση
- Αιφνίδιος θάνατος
- Κύμα Τ
- Myocardial infarction
- Risk stratification
- Repolarization
- QRS-T angle
- Sudden death
- Circadian variation
- T wave
- Electrocardiography
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/24061