Back to search

National and Kapodistrian University of Athens

Εμβιομηχανική μελέτη της επίδρασης της οστεοτομίας της κερκίδας σε περιπτώσεις ψευδαρθρώσεων καταγμάτων του σκαφοειδούς οστού του καρπού με τη χρήση των πεπερασμένων στοιχείων (finite element analysis)

Abstract

dc:description

Aim: The present study s aim was to investigate the effect of distal radius osteotomy in the mechanical behavior of the wrist in cases of carpal scaphoid pseudarthroses using the finite element method. Method: Using data from a CT of the left wrist of a 34year old man and Mimics medical image processing software (Materialise N.V., Belgium) and ANSYS ver. 10 software a finite element model including the distal end of the radius and ulna, the 8 carpal bones and the proximal ⅓ of the metacarpal bones was created. The model included pairs of 2mm thickness articular cartilages between the bones and in total 50 ligaments. Linear elastic isotropic properties were assigned to all of the materials involved in the model. The proximal end of the radius shaft was fully constraint while axial loads along the longitudinal axes of the five metacarpals were applied. The values of the applied load along each ray were in the magnitude of the axial resultant forces present during a grasp function generating 10N (approximately 1kg) with active stabilization of the wrist. Emphasis was given on the bone triplet scaphoid-lunate-radius. 73 finite element models were created and analyzed. The computational time of analysis for each model varied from 14 to 36 hours. We recorded: - The load ratio distribution between the scaphoid-radius and lunate-radius articular surfaces. - The force at the articular surface between scaphoid-lunate. – Displacements. – Strains. – Stresses. Results-Conclusions: In case there is ligament prestress at the early stages after the osteotomy, an ulnar deviation of loads through the radiocarpal joint is recorded. Furthermore, the wrist is more stable. The maximum strains at the pseudarthrosis area are higher resulting in an increase of bone remodeling activity. Thus, the change in anatomic location of maximum strains in the pseudarthrosis area results in new bone remodeling centers appearance. When the wrist balance at a new dynamic state and ligament prestress withdraw, then a bigger ulnar deviation of the loads through the radiocarpal joint is recorded. Wrist becomes more relaxed and the displacement of the bones gets higher while the maximum stains at the pseudarthosis area remain high. The analysis with the finite element method revealed that distal radius osteotomy in a wrist with carpal scaphoid pseudarthrosis has positive effects because it promotes pseudarthrosis healing (increase of stains) and inhibits the onset of osteoarthritic changes at the radiocarpal joint (discharge of scaphoid fossa of the radius). Our results are in agreement with the experimental results of Papachristou et al. and with the published clinical results of this method. We believe that distal radius osteotomy in cases of carpal scaphoid pseudarthroses is an effective procedure and that its positive effects at the biomechanical behavior of the wrist are well documented.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Ξυπνητός, Φραγκίσκος
  • Xypnitos, Fragkiskos

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/24234

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Ξυπνητός, Φραγκίσκος; Xypnitos, Fragkiskos. Εμβιομηχανική μελέτη της επίδρασης της οστεοτομίας της κερκίδας σε περιπτώσεις ψευδαρθρώσεων καταγμάτων του σκαφοειδούς οστού του καρπού με τη χρήση των πεπερασμένων στοιχείων (finite element analysis). National and Kapodistrian University of Athens, 2009. http://hdl.handle.net/10442/hedi/24234