University of Crete (UOC)
Κακώσεις κάμψης-διάτασης της αυχενικής μοίρας της σπονδυλικής στήλης (εξάρθρημα ΑΜΣΣ): Σταθεροποίηση μετά από πρόσθια δισκεκτομή και σπονδυλοδεσία με σύστημα άκαμπτης πλάκας και οστικό μόσχευμα: εμβιομηχανική μελέτη
Abstract
dc:descriptionHypothesis: Anterior cervical fusion with a wedged graft and a locked plate can effectively stabilize the cervical spine after complete anterior and posterior segmental ligamentous release. Methods: A three step approach was used in this study. STEP A: First a feasibility study was conducted with lumbar spine specimens to investigate the kinematics under preload using an in vitro three-dimensional (3-D) flexibility test. A total of 21 lumbar spine specimens were utilized for this flexibility investigation as part of other research programs. STEP Β: The results of the first experiment were then applied in the cervical spine where room for technical error is small compared to the lumbar spine. A total of six cervical spine specimens were used. Three different preloads (0N 150N 250N) and three different moments (0.8, 1.5, 2.5 Nm) were used to investigate lower cervical spine kinematics under preload. STEP C: In the main experiment eight fresh frozen human lower cervical spines (C3-C7) from young donors (age 44.5 years range 21-63) were used. A 3-D flexibility test was conducted using a moment of 0.8 Nm without preload. Flexion-extension was additionally tested using a moment of 1.5 Nm under 0N and 150N follower preload. Spines were tested first intact then after complete C5-C6 discectomy with PLL resection and ACDF with a wedged bone graft and a rigid locked plate and finally after complete release of the supraspinous, interspinous and intertransverse ligaments, the facet capsules and ligamentum flavum. Results: STEP A: From the lumbar spine kinematics experiment it was concluded that preload significantly affects the kinematics of human spine specimens in flexion extension. The optimization of the path provides the best conditions for near normal kinematics. STEP Β: From the cervical preload paper it was determined that preload is not affecting only saggital plane motion. Kinematics in lateral bending and axial rotation are severely affected by the experimental set up. Preload is therefore recommended only in flexion extension kinematics. STEP C: When tested under 0.8 Nm moment without preload complete posterior and anterior ligamentous release did not significantly increase the ROM of the ACDF construct in flexion-extension (p>0.05) lateral bending (p>0.05) and axial rotation (p>0.05). When tested under 1.5 Nm moment without a preload flexion-extension tended to increase significantly after ligamentous release as compared to ACDF with intact posterior ligaments (p=0.08). However, this difference was negated (p>0.05) after the application of a compressive preload. The ROM of the ACDF construct with the simulated DFS-3 injury remained significantly smaller than intact in all tested directions (p<0.05). Conclusions: Preload is an important characteristic of living tissue and should always be considered if meaningful clinical messages are to be expected from biomechanical studies. Anterior cervical fusion with a wedged graft and a rigid constrained (locked) plate can effectively stabilize the non-osteoporotic cervical spine after complete posterior element injury when excessive range of motion is prevented (for example by the use of postoperative external immobilization). Even when the construct is subjected to higher moments adequate stability can be achieved when physiologic preload is present. Osteoporosis and lack of sufficient preload due to poor neuromuscular control may affect long term screw stability and additional external immobilization may be needed until fusion matures.
Degree
thesis:*- Grantor dc:publisher
- University of Crete (UOC)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Paxinos, Odysseas
- Παξινός, Οδυσσέας
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/24559