Agricultural University of Athens
Εφαρμογή αισθητήρων βιοηλεκτρικής αναγνώρισης (BERA) νεότερης γενιάς στην ιολογία
Abstract
dc:descriptionIn the present PhD thesis the development of a cell-biosensor basic structure is described, which might detect, in minimal time and with satisfactory sensitivity, antigens and antibodies of viruses. The methodological approach is focused on the use of established laboratory techniques in biology, based on Bioelectric Recognition Assay (BERA), for the development of a simple operating system for the detection of viruses, in plants and humans. The use of electroporation is also described, for the preparation of “membrane-engineered” cells displaying a specific response to certain viruses. As representative example Vero fibroblasts were used, in the membrane of which, were inserted antibodies of CMV or TRV. The attachment of the homologous virus triggered the change of the cell membrane potential. All cells were immobilized in an alginate matrix. Regarding the first experimental part, the attachment of CMV on the cell-biosensor cells, bearing the homologous antibody and respectively in the studies with TRV, had as result the measurable change of the “membrane-engineered” cells’ potential. On the contrary the presence of non-homologous viruses such as CGMMV and PVY did not trigger any change. The above results were also confirmed with the use of fluorescence microscopy, where the presence of a homologous virus caused the change of Ca2+ concentration in the cytoplasm. The same process was applied to pure virus solutions in different dilutions: 0.0 ng ml-1 (control), 5.0, 7.0, 10.0, 13.0 and 20.0 ng ml-1 and in the case of TRV the results were encouraging regarding the possibility of quantitative determination of the virus. A short study was carried out as well, in order to evaluate the reaction of Vero cells, which were not “membrane engineered”, to the presence of TRV and CGMMV. The reaction was not specific, but it was obvious that the viruses’ presence triggered changes to the cell membrane potential.The development of a BERA biosensor as an application for the detection of hepatitis viruses was based on the same method. Two applications took place: The first application was related to the insertion, by electroporosis, of antibodies (anti-HBs, anti-HBe) on the membrane surface, for the detection of homologous antigens of HBV. The second application regarded the insertion of the antigen of the homologous virus (HBsAg) for the detection of the corresponding homologous antibody (anti-HBs). An alginate matrix was used as well for the immobilization of the “membrane engineered” cells. The method was applied on clinical samples; whereas hepatitis C virus (HCV) was used as the heterologous virus. The results showed that, in a very short time period (approximately 45 seconds) it is possible to detect virus elements, as well as to obtain information regarding the patient’s infectivity stage. The specificity of BERA biosensors based on “membrane engineered” cells depends from the specialisation of the antibodies or antigens, inserted on the surface of the cellular membrane. Consequently the described methodological approach incorporates similar disadvantages with the immunological methods. However it has other advantages such as sensitivity, short time response and reproducibility. Comparatively with the optical and electrochemical biosensors, the described in the present study system, has an additional advantage, which is the one step process. It should pointed out that the described method is a preliminary stage for the development of a biosensor system, based on “membrane-engineered” cells, incorporating a specialisation to the molecule, chemical compound or micro-organism that is going to be analyzed. A short study was carried out also in this case, in order to evaluate the reaction of Vero cells, which were not “engineered”, to the presence of HBsAg and HCV. The reaction was not specific, but it was concluded that the cell membrane potential values were following a linear pattern, in both cases.We examined the possibility to develop a biosensor for the detection of plant viruses, which would be more stable. For the construction of the sensor an automated system was developed and the biosensor itself was produced it the wells of an ELISA plate. The method was applied for TRV, CMV and PVY. The samples were purified virus or infected plant tissues. Three different concentrations were used 1, 10 and 100ngml-1. The results were very encouraging and at the first stage it was made possible to detect a virus in single and in mixed infections and to define the lower detection limit, which was similar with ELISA method’s respective limit (1ngml-1). It was shown also the possibility to quantify a virus in a sample. In order to study the performance of BERA sensors, a comparative analysis took place and an amperometric sensor was developed, specialized in the detection of PVY. The amperometric sensor succeeded in differentiating positive from non-positive samples (nonhomologous viruses or negative samples), but the detection limit was higher compared to the respective limit of BERA sensors. Consequently this sensor is not suitable for screening of plant tissue samples with low virus concentration, contrary to the BERA sensors developed in the present thesis
Degree
thesis:*- Grantor dc:publisher
- Agricultural University of Athens
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Perdikaris, Antonios
- Περδικάρης, Αντώνιος
Subjects
dc:subject × 17- Κυτταρικοί βιοαισθητήρες
- Βιοηλεκτρική μέθοδος αναγνώρισης Αναγνώρισης
- Iοί υπατίτιδας
- Κύτταρα Vero
- Ηλεκτροπόρωση
- TRV
- CMV
- PVY
- Cell biosensor
- Bioelectric recognition assay
- Hepatitis viruses
- Vero cells
- Electroporation
- Γεωπονικές Επιστήμες και Κτηνιατρική
- Γεωπονική Βιοτεχνολογία
- Agricultural and Veterinary Sciences
- Agricultural Biotechnology
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/24829