Aristotle University Of Thessaloniki (AUTH)
Μελέτη του μηχανισμού θραύσης μηχανοκίνητων μικροεργαλείων ενδοδοντίας νικελίου-τιτανίου σε ευθείς και κεκαμμένους ριζικούς σωλήνες
Abstract
dc:descriptionThe aim of this Doctoral Thesis was to investigate the effect of root canal curvature on the failure mechanism of rotary Ni-Ti endodontic instruments of the ProFile system (Dentsply Maillefer, Ballaigues, Switzerland) under standardized simulated clinical conditions for a known number of consecutive uses. Three hundred mesial root canals from freshly extracted human mandibular molars were used. Root canals were divided into 3 groups according to the angle and radius of curvature according to Pruett et al. (1997): straight (group A: angle 0+10o, radius 0mm), moderately curved (group B: angle 30±10o, radius 2±1mm) and severely curved (group C: angle 60±10o, radius 2±1mm). All instrumentations were performed in the department of Endodontology (Dental School, Aristotle University of Thessaloniki), by a single operator and root canals were enlarged according to the manufacturer’s protocol up to instrument taper .06 size # 25 at working length. Prior to the first use and after the completion of each instrumentation instruments were cleaned in an ultrasonic bath and autoclaved. Instruments that concluded instru¬mentation of 20 root canals, fractured or were plastically deformed without fracture, were retrieved and substituted. Kaplan-Meier method was used for survival analysis and post hoc test (Cox- Mantel) for determination of significant differences (a=0.05). Selected instruments were investigated by means of computerized X-ray microtomography, in order to detect any internal defects. Fractured instruments were subjected to fractographic analysis under SEM. Finally all instruments used were viewed under the metallographic microscope in order to identify any sign of crack propagation. Investigation of the instruments with computerized X-ray microtomography and investigation under SEM and the metallographic microscope were performed in the Department of Dental Biomaterials, Dental School, National and Kapodistrian University of Athens. Instruments presented fracture arbitrarily from 1 to 20 uses in moderately and severely curved canals. Regardless of the type of the instrument, fracture and failure were statisti¬cally more frequent in group C. After 10 uses survival probability was 90% for group A, 80% for group Β and 60% for group C. After 20 uses there was a further reduction by 5%, 20% and 35% for groups A, B and C respectively. During the inspection with computerized X-ray microtomography and under the metallographic microscope no cracks were detected in unused instruments, fractured instruments, deformed instruments and those that concluded the instru¬mentation of 20 root canals. SEM fractographic examination revealed the presence of tensile fracture with the predominance of dimples, whereas no cracks were detected. The abruptness of root canal curvature negatively affects the failure rate of rotary Ni-Ti instruments and predisposes to fracture. The results of fracture incidence were corroborated by the results of the microscopic inspection with the absence of cracks and the detection of dimples, characteristic pattern of tensile fracture. Therefore it is safe to conclude that fracture was caused by a single overload of the rotating instrument and was not related to a gradual degra¬dation caused by fatigue.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kosti, Eleni
- Κωστή, Ελένη
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/25105