Back to search

National Technical University of Athens (NTUA)

Μαθηματική μοντελοποίηση της θερμικής άνεσης και της ποιότητας εσωτερικού αέρα και προχωρημένες τεχνικές βελτιστοποίησης του κτιριακού σχεδιασμού: εφαρμογές σε φυσικά αεριζόμενα κτίρια

Abstract

dc:description

The present dissertation investigates the airflow pattern in naturally ventilated buildings using advanced computer simulation techniques such as field or Computational Fluid Dynamics (CFD) models. In particular, two-equation turbulence models, such as the Standard k-ε, the RNG k-ε, the “Realizable” k-ε, as well as the Reynolds Stress Model (RSM) are used to predict the flow field in and around the buildings considered. In the case of the Standard k-ε model the potential of improving the prediction accuracy is investigated by means of the following ways: (a) Application of a Two-layer Standard k-ε model, and (b) Modification according to the inlet flow variables profiles of the Atmospheric Boundary Layer (ABL). The aforementioned turbulence models and the proposed modifications are passive ventilation of a pilot building and of a real-scale building subject to actual passive ventilation (for which an experimental procedure is conducted). The CFD model is then used for the prediction of thermal comfort in naturally ventilated buildings by implementing the most appropriate thermal comfort indices (TCI), such as the Predicted Mean Vote (PMV), which, according to literature information, is modified for pure natural ventilation as follows: (a) Extension to account for the metabolic-rate reduction expected in warm environments and for the expectancy factor due to occupant’s habitat, and (b) Correction of the PMV for humidity effects, based on the Standard Effective Temperature (SET*). The present thermal comfort model is completed with the implementation of the Percentage Dissatisfied (PD) index to account for discomfort due to air draughts as well. Additionally, Indoor Air Quality (IAQ) indices are also implemented in the CFD model, i.e. the ventilation effectiveness related to the removal of common pollutants. Following the aforementioned coupled model (CFD-TC/IAQ) a database of input-output pairs is formed, which is used to train and validate radial basis functions (RBF) artificial neural networks (ANN) according to the fuzzy means method. The ANN distributions are then utilized to formulate a multiobjective optimization problem, which accounts for the available thermal comfort and indoor air quality indices, occupant activity level and special constraints provided by design guidelines. The problem is confronted using a gradient-based algorithm associated with a special handling of constraints and of the initialization space of the design variables (Initialization Grid Concept, IGC). Additionally, a technique to account for the non-dominated solutions of the objective functions according to the Pareto criteria is also introduced. Finally, for each case studied the optimal designs are presented by means of nomographs, which may serve as look-up tables for either decision-making strategies or automated systems to create “Intelligent Buildings”.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Stavrakakis, Georgios
  • Σταυρακάκης, Γεώργιος

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/25592

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Stavrakakis, Georgios; Σταυρακάκης, Γεώργιος. Μαθηματική μοντελοποίηση της θερμικής άνεσης και της ποιότητας εσωτερικού αέρα και προχωρημένες τεχνικές βελτιστοποίησης του κτιριακού σχεδιασμού: εφαρμογές σε φυσικά αεριζόμενα κτίρια. National Technical University of Athens (NTUA), 2010. http://hdl.handle.net/10442/hedi/25592