Optimization of magnification mammography using monte carlo simulation techniques
Abstract
dc:descriptionIn the framework of this doctorate thesis, two simulation models based on Monte Carlo were expanded in order to include magnification geometries and various breast compositions, and were utilized aiming to study and optimize the magnification views in mammography. With the use of these models, dosimetric as well as image quality characteristics were evaluated and combined in order to come into conclusions. More specifically, the dose in the glandular tissue of the breast, which is directly associated with the carcinogenic risk during mammography, was found to increase with the degree of magnification, mainly due to the inverse square law. Contrast to Noise Ratio also increases with magnification. However, the increase rate is higher for magnification up to 1.4. With the introduction of a Performance Index, which is a function of the desirable benefit (expressed by the (CNR)ν) and the cost (expressed by the dose), several exposure and design parameters (degree of magnification, spectrum) were evaluated under magnification conditions. Degree of magnification 1.3 was found to have the best overall performance for all the anode/filter combinations considered. Several combinations like W/0.050mmAl, Rh/0.51mmAl, W/0.030mmRh, Rh/0.029mmRh, Rh/0.030mmRu and Mo/0.029mmRh can compete with the Mo/0.030mmMo under contact geometry. However, when magnification is performed and especially degree higher than 1.3, Mo/0.030mmMo has the best overall performance between the anode/filter combinations considered. Moreover, the effect of focal spot size and x-ray intensity distribution on the spatial resolution was studied under magnification, using the edge method. Focal spots larger than 0.12 mm should be utilized only for screening mammography, especially when combined with uniform or double Gaussian intensity distributions. Small focal spots of 0.04 mm or less, combined with Gaussian distribution result in acceptable values of spatial resolution, according to the international regulations, even for high degrees of magnification. Finally, a degradation of the spatial resolution was found with the degree of magnification, which is mainly caused by the geometrical unsharpness.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Koutalonis, Matthaios
- Κουταλώνης, Ματθαίος
Subjects
dc:subject × 14Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/25782