Back to search

University of Patras

Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου

Abstract

dc:description

Purpose: Drug eluting stents (DES) proved to minimize neointimal hyperplasia in coronary vessels. Hyperplastic reaction is the most common unwelcome event related to the use of metal mesh stents in the ureter. We evaluated the effect of zotarolimus eluting stent (ZES- Endeavor Resolute, Medtronics Inc, USA) in porcine and rabbit ureter. Methods: A ZES and a bare metal stent (BMS) were inserted in each ureter of 10 pigs and 6 rabbits. The insertion was performed by retrograde approach. Computerized tomography (CT) was used for the evaluation of porcine ureters while intraoperative intravenous pyelography (IVP) for rabbit ureters. The follow-up included CT or IVP every week for the following 4 weeks for pigs and 8 weeks for rabbits. Renal scintigraphies were performed prior to stent insertion and during the 3rd week in all animals. Optical coherence tomography (OCT) has been used for the evaluation of the luminal and intraluminal condition of the stented ureters. Histopathologic examination of the stented ureters embedded in glycol-methacrylate was performed. Results: Hyperplastic reaction was present in both stent types. BMSs in 7 porcine ureters were completely obstructed while porcine ureters stented with ZES had hyperplastic tissue which did not result in obstruction. Two rabbit ureters stented by BMS were occluded while no ZES was associated with ureteral obstruction. The function of the 7 porcine renal units and the two rabbit units with obstructed stented ureter was compromised. The OCT revealed increased hyperplastic reaction in the ureters stented by BMSs in comparison to ZESs. Although, hyperplastic reaction was present in all cases, pathology examination revealed significantly more hyperplastic reaction in BMSs. Conclusion: ZESs in the pig and rabbit ureter were not related to hyperplastic reaction resulting in stent occlusion. These stents were related to significantly lower hyperplastic reaction in comparison to BMSs while inflammation rates were similar for both stent types.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kallidonis, Panagiotis
  • Καλληδώνης, Παναγιώτης

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/26106

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kallidonis, Panagiotis; Καλληδώνης, Παναγιώτης. Η χρήση των εμποτισμένων με φάρμακα μεταλλικών ενδοπροθέσεων στον ουρητήρα πειραματικού μοντέλου. University of Patras, 2011. http://hdl.handle.net/10442/hedi/26106