Back to search

University of Patras

Αυτόματη διάγνωση μαστογραφικών μικροαποτιτανώσεων με ανάλυση μορφολογίας

Abstract

dc:description

Accurate segmentation of microcalcifications (MCs) in mammography is crucial for the quantification of morphologic properties by features incorporated in computer aided diagnosis (CADx) schemes. A novel segmentation method is proposed adaptive to coarse scale selection to initialize the segmentation algorithm by means of scale space signatures. Also we suggest the analysis in the continuous wavelet transform offering a rich multiscale frame. In this framework multiscale active contours are introduced utilizing as initial step the previously proposed. Active Rays method combined to linear interpolation for initial contour estimation. Then each contour point follows the direction where the gradient is maximized MCs are finally delineated by refining each contour point position at finer scales more accurately. A radial gradient method representing the current state of the art was also implemented for comparative purposes. Segmentation accuracy was quantitatively assessed by means of the Area Overlap Measure utilizing manual segmentation of individual MCs as ground truth provided by expert radiologists. A total of 1157 individual MCs were segmented in a dataset of 128 MC clusters digitized at 50μm pixel resolution. To further ensure feature reliability features extracted from the improved segmentation method were compared (Pearson correlation) to features extracted from manual experts delineations. Following four CADx schemes were implemented utilizing Least Square Minimum Distance (LSMD) classifier and morphology features extracted from the two proposed and the Radial Gradient method. Training of all classifiers was accomplished by features extracted from manually segmented MCs. Classification performance was evaluated by means of the area under ROC curve (Az). Quantitative analysis indicated that Multiscale Active Contour method initialized by Active Rays (MAC AR) had similar Area Overlap Measure performance either for small and large MCs. Furthermore, the improved method demonstrated better performance in terms of classification performance (Az=0.78) as compared to the radial gradient one (Az=0.67) however, statistically similar to manual segmentation, representing the best performance (Az=0 81).

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Arikidis, Nikolaos
  • Αρικίδης, Νικόλαος

Subjects

dc:subject × 18

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/26447

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Arikidis, Nikolaos; Αρικίδης, Νικόλαος. Αυτόματη διάγνωση μαστογραφικών μικροαποτιτανώσεων με ανάλυση μορφολογίας. University of Patras, 2009. http://hdl.handle.net/10442/hedi/26447