National and Kapodistrian University of Athens
Κατασκευή βιοαισθητήρων που στηρίζονται σε λιπιδικές μεμβράνες με συνθετικούς υποδοχείς για την ανίχνευση τοξικών ουσιών σε τρόφιμα, νερ...
Abstract
dc:descriptionThe Ph.D. thesis involved the study, design of optical and electrochemical bilayer lipid membranebased biosensors for compounds of biomedical, environmental and industrial interest. The present work reports a technique for the construction of portable devices that are based on stabilized lipid membrane with an incorporated artificial receptor (i.e., hydroxy or permethoxy calixarene derivative) that can be used for the rapid optical detection of doping materials in human urine. The artificial receptors are incorporated within the lipid mixture prior to polymerization. The polymerization process takes place by using UV irradiation instead of heating at 60 oC. Microporous filters composed off glass fibers were used as supports for the stabilization of these sensors. The lipid film was formed on the filter by polymerization, using UV irradiation prior to its use. Methacrylic acid was the functional monomer, ethylene glycol dimethacrylate was the crosslinker and 2, 2’- azobis-(2-methylpropionitrile) was the initiator. The polymerization is completed within 4 h and the artificial receptors retain their activity. These devices provided a simple screening sensitive spot optical test for the rapid one-shot detection of dopamine and ephedrine (using the hydroxy and permethoxy receptors, respectively, in the lipid films during polymerisation) in human urine. The lipid films without the receptors provided fluorescence under a UV lamp. The use of the receptors in these films quenched this fluorescence and the color became similar to that of the filters without the lipid films. A drop of urine containing dopamine or ephedrine provided a ''switching on'' of the 110 flourescence which allows the rapid detection of these stimulants in human urine at the levels of 10-9 M concentrations. The technique is now based on a calibration graph and therefore as a quantitative method for the detection of dopamine or ephedrine in real samples of urine is provided herein that can be complimentary to HPLC methods. The mechanism of signal generation was investigated in the present paper by using differential scanning calorimetric (DSC) measurements. The construction of these devices allows the practical use of the techniques for chemical sensing, based on lipid membranes to prepare portable devices for the optical detection of toxicants in environmental, clinical samples or foods in the field, and further commercialization of these devices. The present technique describes the preparation of a selective receptor for carbofuran and the development of a simple sensitive spot optical test for the rapid one-shot detection of carbofuran using stabilized lipid films supported on a methacrylate polymer on a glass fiber filter with incorporated artificial receptor. The selective receptor was synthesized by a chemical reaction using a resorcin[4]arene receptor by transforming all the –OH groups into phosphoryl groups. The lipid films without this receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence and the colour became similar to that of the filters without the lipid films. A drop of aqueous solution of carbofuran provided a “switching on” of the fluorescence which allows the rapid detection of this stimulant at the levels of 10-9 M concentrations. The effect of potent interferences included a wide range of compounds. The results showed no interferences from these compounds in concentration levels usually found in real samples. The effect of interference of proteins and lipids was also examined. The reproducibility of the method was checked in about 100 samples and all of them were found to provide similar results. The device was tested/ evaluated in real samples of fruits, vegetables and dairy products. Note that the colours of the filters remain stable for periods of more than two months.The present paper describes a technique for the rapid, selective and sensitive electrochemical flow injection analysis (FIA) of carbofuran in foods using stabilized after storage in air lipid membranes in which the receptor was incorporated. Injections of carbofuran followed into flowing streams of a carrier electrolyte solution. A complex formation between the calix[4]arene receptor and carbofuran takes place through hydrogen bonding [the benzene group of carbamate to be intercalated within the 111 cavity of the receptor molecule] that enhances the preconcentration of carbofuran at the lipid membrane surface which in turn causes dynamic alterations of the electrostatic fields and phase structure of membranes; as a result ion current transients were obtained and the magnitude of these signals was correlated to carbofuran concentration, which could be determined at the nanomolar level. The response times were ca. 1 min. The investigation of the effect of potent interferences included a wide range of compounds usually found in foods and also proteins and lipids. The present method now provides a technique for the rapid detection of carbofuran at the levels of nM concentrations without interferences from the other constituents and can be used as complimentary rapid technique to HPLC methods. The present paper describes the use of a phosphoryl derivative of a resorcin[4]arene receptor for the development of a chemosensor for the rapid, selective and sensitive electrochemical flow injection analysis (FIA) of zinc in natural tap, synthesized and mineral water, without any laborious and time-consuming treatment; the sensor is based on stabilized after storage in air lipid membranes in which the receptor was incorporated. The device can sense an analyte in a drop (50-100 μL) of sample. Injections of zinc were made into flowing streams of a carrier electrolyte solution. A complex formation between the calix[4]arene receptor and zinc takes place that enhances the preconcentration of zinc at the lipid membrane surface which in turn causes dynamic alterations of the electrostatic fields and phase structure of membranes; as a result ion current transients were obtained and the magnitude of these signals was correlated to zinc concentration, which could be determined at the nanomolar level. The response times were ca. 5 sec. The investigation of the effect of potent interferences included other metals and compounds usually found in real samples of waters
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Raftopoulou, Garyfallia
- Ραφτοπούλου, Γαρυφαλλιά
Subjects
dc:subject × 19- Βιοαισθητήρες
- Λιπιδικές μεμβράνες
- Ριζορκιν[4]αρένια
- Ντοπαμίνη - εφεδρίνη
- Καρβοφουράνιο
- Φθορισμός
- Μέθοδος έκχυσης δείγματος σε ροή ηλεκτρολύτη
- Ανίχνευση ψευδαργύρου σε δείγματα νερού
- Biosensors
- Lipids membranes
- Resorcin[4]arene
- Dopamine - ephedrine
- Carbofuran
- Flyorescence
- Flow injection analysis (FIA)
- Φυσικές Επιστήμες
- Χημεία
- Natural Sciences
- Chemical Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/26462