Back to search

University of Patras

Ανάπτυξη υπολογιστικού μοντέλου προσομοίωσης φθοριζόντων υλικών ανιχνευτών ιατρικής απεικόνισης με τεχνικές Monte Carlo

Abstract

dc:description

The intrinsic phosphor properties are of significant importance for the performance of phosphor screens used in medical imaging systems. In previous analytical theoretical and Monte Carlo studies on granular phosphor materials values of optical properties and light interaction cross sections were found by fitting to experimental data. These values were then employed for the assessment of phosphor screen imaging performance. However it was found that depending on the experimental technique and fitting methodology the optical parameters of a specific phosphor material varied within a wide range of values i.e. variations of light scattering with respect to light absorption coefficients were often observed for the same phosphor material In this study x-ray and light transport within granular phosphor materials were studied by developing a computational model using Monte Carlo methods. The model was based on the intrinsic physical characteristics of the phosphor. Input values required to feed the model can be easily obtained from tabulated data. The complex refractive index was introduced and microscopic probabilities for light interactions were produced using Mie scattering theory. Model validation was earned out by comparing model results on x-ray and light parameters (x-ray absorption statistical fluctuations in the x-ray to light conversion process number of emitted light photons output light spatial distribution) with previous published experimental data on Gd₂O₂S:Tb phosphor material (Kodak Min R screen). Results showed the dependence of the modulation transfer function (MTF) on phosphor gram size and material packing density. It was predicted that granular Gd₂O₂S:Tb screens of high packing density and small gram size may exhibit considerably better resolution and light emission properties than the conventional Gd₂O₂S:Tb screens under similar conditions (x-ray incident energy screen thickness).

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Liaparinos, Panagiotis
  • Λιαπαρίνος, Παναγιώτης

Subjects

dc:subject × 12

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/26517

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Liaparinos, Panagiotis; Λιαπαρίνος, Παναγιώτης. Ανάπτυξη υπολογιστικού μοντέλου προσομοίωσης φθοριζόντων υλικών ανιχνευτών ιατρικής απεικόνισης με τεχνικές Monte Carlo. University of Patras, 2007. http://hdl.handle.net/10442/hedi/26517