Back to search

University of Patras

Διερεύνηση συμπεριφοράς μονωτήρων υψηλής τάσης μέσω μετρήσεων του ρεύματος διαρροής

Abstract

dc:description

Leakage current monitoring is a widely applied technique for monitoring surface activity and condition of high voltage insulators. Field monitoring is necessary to acquire an exact image of activity and performance in the field. However recording, managing and interpreting leakage current waveforms the shape of which is correlated to surface activity is a major task. The problem is commonly by-passed with the extraction, recording and investigation of values related to peak and charge an approach reported to produce questionable results. The present thesis focuses on the investigation and classification of field leakage current waveforms. At first a detailed background of measuring and analyzing leakage current both in lab and field conditions is provided. Then, the monitoring sites two 150kV Substations as well as the developed custom-made software and the newly constructed High Voltage Test Station where the results of this thesis are to be implemented, is briefly described. More than 100.000 waveforms are investigated recorded through a period exceeding ten years. Field related noise is thoroughly described and evaluated. Three different types of noise are identified and their impact on the size of accumulated data and on data interpretation is investigated. Three different techniques to overcome the problem are applied and evaluated. Activity portraying waveforms are further investigated. Further classification of activity portraying waveforms is performed employing signal processing feature extraction and selection algorithms as well as pattern recognition techniques such as Wavelet Multi-Resolution Analysis, Fourier Analysis, Neural Networks (NNs), student’s t-test, minimum Redundancy Maximum Relevance (mRMR), k-Nearest Neighbors (kNN), Naive Bayesian Classifier and Support Vector Machines (SVMs). Overall results provide a full image of the various aspects of field leakage current monitoring. A detailed image of field waveforms, revealing several new attributes, is documented. New approaches for the classification of leakage current waveforms are introduced applied on field waveforms and evaluated. Results described in this thesis significantly enhance the effectiveness of the leakage current monitoring technique providing a powerful tool for the investigation of surface activity and performance of high voltage insulators.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Pylarinos, Dionysios
  • Πυλαρινός, Διονύσιος

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/26855

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Pylarinos, Dionysios; Πυλαρινός, Διονύσιος. Διερεύνηση συμπεριφοράς μονωτήρων υψηλής τάσης μέσω μετρήσεων του ρεύματος διαρροής. University of Patras, 2012. http://hdl.handle.net/10442/hedi/26855