Back to search

Aristotle University Of Thessaloniki (AUTH)

Μελέτη διφασικών ροών σε αναδευόμενα δοχεία

Abstract

dc:description

In the present work, an electrical, conductimetric, technique with wall-mounted ring electrodes was chosen. This technique combines the ease of a simple conductimetric technique with the plentifulness of local measurements of a tomographic technique. This main technique was combined and in the same time verified, by hydrostatic pressure measurement and free surface video recording. Finally, a photographic technique was applied for the measurement of the bubble size distribution (BSD) near the vessel wall. The gas-liquid, stirred reactor system of the present study was customized for variable agitation speed, air volume supply and for the liquid phase physical properties of surface tension, viscosity and salinity. The following quantities were measured: local gas holdup near the tank wall (first layer) and at the second layer; total gas holdup for the reactor (by three techniques) and the BSDs. Also, the data from the electrical technique were analyzed with the Gas Disengagement method. From the gathered results it can be concluded that: - The accuracy of the electrical technique is very good and satisfactory. - Total holdups have shown an ambiguous (according to the current literature) behavior versus the viscosity of the liquid phase; the holdup is increasing with increased viscosity up to 5 mPa.s, while any farther increase leads to lowered holdup. - Local holdups are depended from all the studied parameters, demonstrating vertical profiles with a peak of holdup near the height of the impeller. - BSDs have shown a rational independence from the mechanical parameters of agitation speed and bubble supply, indicating the fact that at the measuring volume of the present study there aren’t present any coalescence nor breakage phenomena. - The Gas Disengagement analysis have shown that the participation of the small bubbles to the local holdup (and accordingly to the total holdup) is very important. It was proven that the participation of the small bubbles has increased (at the expense of the larger ones) by reducing the surface tension, while the increase in viscosity leads to decrease of small bubbles participation to the local holdup without affecting the larger ones. These remarks are in accordance with the dependencies of the total holdup measurements, observed for the physical properties parameters.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Σαμαράς, Κωνσταντίνος
  • Samaras, Konstantinos

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/27402

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Σαμαράς, Κωνσταντίνος; Samaras, Konstantinos. Μελέτη διφασικών ροών σε αναδευόμενα δοχεία. Aristotle University Of Thessaloniki (AUTH), 2010. http://hdl.handle.net/10442/hedi/27402