Back to search

National and Kapodistrian University of Athens

Σύγκριση των δυνάμεων και των ροπών που αναπτύσσονται κατά την ορθοδοντική εμβύθιση τομέων με τρία διαφορετικά εμβιομηχανικά συστήματα

Abstract

dc:description

The aim of this study was to comparatively evaluate the intrusive/extrusive forces and buccolingual torquing moments generated during anterior intrusion using different incisor intrusion mechanics. Five wire specimens were used for each of the following intrusive arches and for each jaw: blue Elgiloy non-heat treated utility arch 0.016 x 0.016-inch; TMA utility arch 0.017 x 0.025-inch; Burstone TMA intrusion arch 0.017 x 0.025-inch; and reverse curve of Spee NiTi 0.016 x 0.022-inch only for upper jaw. The wires were inserted on bracketed dental arches constructed on Frasaco models, segmented mesially to the canines. Simulated extrusion of the incisors from 0.0-3 mm was performed using the Orthodontic Measurement and Simulation System (OMSS), and forces and moments were recorded in the saggital plane at 0.1mm vertical displacement increments. All measurements were repeated five times for each specimen. The values recorded at 1.5mm for all wires were used for the statistical evaluations for the anterior regions and the values recorded at 3.0mm were used for the statistical evaluations for the posterior regions. The results were analyzed with analysis of variance (nested ANOVA, two-way ANOVA) with forces and moments serving as the dependent variables and wire type as the independent variable. Post-hoc multiple comparisons were performed using the Tukey test (0.05 error rate). The comparison of the two major intrusion techniques for the maxillary anterior teeth, segmented and bioprogressive, regarding the anterior regions (at 1.5mm of incisor displacement), revealed that the Burstone TMA 0.017 x 0.025-inch intrusion arch exerted the lowest force on the incisors (upper 0.99 N, lower 1.25 N), followed by the TMA utility 0.017 x 0.025-inch (upper 1.33 N, lower 1.54 N) and the blue Elgiloy 0.016 x 0.016-inch utility (upper 1.43 N, lower 1.71 N). The highest force was recorded for the reverse curve of Spee NiTi and exceeded the value of 9 N. The lowest buccolingual moments were recorded with the upper Burstone intrusion arch (2.47 Nmm), whereas the highest was registered for the lower utility arch constructed with a 0.017 x 0.025-inch TMA wire (7.79 Nmm). Regarding the posterior regions (at 3.0mm of incisor displacement), the 0.016 x 0.016-inch Blue Elgiloy utility arch exerted the highest posterior extrusive forces, 15% higher than the 0.017 x 0.025-inch TMA utility and 40% higher in comparison with the 0.017 x 0.025-inch TMA Burstone intrusion arch.The lowest posterior moment in the saggital plane was generated by the 0.017 x 0.025-inch TMA Burstone intrusion arch. The 0.016 x 0.016-inch Blue Elgiloy utility arch exerted 15% higher posterior moments and the 0.017 x 0.025-inch TMA utility 25% higher. Forces and moments were consistently larger for the mandible compared to the maxilla for the same intrusion technique.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Sifakakis, Iosif
  • Σηφακάκης, Ιωσήφ

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/27414

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Sifakakis, Iosif; Σηφακάκης, Ιωσήφ. Σύγκριση των δυνάμεων και των ροπών που αναπτύσσονται κατά την ορθοδοντική εμβύθιση τομέων με τρία διαφορετικά εμβιομηχανικά συστήματα. National and Kapodistrian University of Athens, 2009. http://hdl.handle.net/10442/hedi/27414