Aristotle University Of Thessaloniki (AUTH)
Καταγραφή και ανάλυση του ήχου της αρτηριοφλεβικής αναστόμωσης σε αιμοκαθαιρόμενους ασθενείς
Abstract
dc:descriptionBackground: Clinical examination of generated bruit and thrill represents the easiest and most popular method of assessment for the arteriovenous fistula function. The aim of this study was to assess and analyze sound frequency and sound intensity of the produced bruit, with the assist of a computerized method, in order to build an objective, easy-to-perform, bedside technique of fistula function evaluation. Methods: A total of 149 prevalent hemodialysis patients with functioning (n=121), or non-functioning (n=28) native upper-arm AVF were included in the study. They underwent sound analysis of the bruit generated from the AVF prior to the mid-week dialysis session, with the use of an electronic stethoscope (sensitivity 20-20,000Hz) connected to a portable computer. Sound files were created and Fast Fourier Transformation (FFT) was used in order to further process the recordings. In a subset of 51 patients, fistula function and blood flow in ml/min was assessed with a standard color Doppler ultrasound examination in order to validate the sound analysis recordings. Results: The mean age of the patients was 63.5 ± 14.3 years and the median vintage time 39.6 (range 1 to 200) months. The analysis of sound revealed that minimum sound intensity varied from -71.9 to -2.29 dB (mean -16.8 dB; median -14.9dB), and the maximum sound intensity varied from -18.4 to -0.49 dB (mean -3.2 dB; median - 1.0 dB). In the subset of patients that underwent a Doppler test, the mean blood flow was 857.7 ± 448.3 ml/min and was significantly correlated with maximum sound intensity (r=0.563; p=0,012). The ROC curve revealed an area under the curve of 0.849 (CI: 0.72-0.97); p= 0.000019, conferring a sensitivity of 79.2% and a specificity of 89.9% when using a cut-off value of -10.06 dB in sound intensity for the discrimination between well-functioning (blood flow ≥600 ml/min) and malfunctioning fistulas. Conclusions: This study is the first attempt of computer assisted sound assessment of the AVF bruit. Sound analysis with this method is simple, inexpensive, and a valid estimation of AVF function.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Malindretos, Pavlos
- Μαλινδρέτος, Παύλος
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/27615