National and Kapodistrian University of Athens
Εμβιομηχανική και κλινική μελέτη της οστεοσύνθεσης υποκεφαλικών καταγμάτων μηριαίου με τρεις αποκλίνοντες αυλοφόρους κοχλίες δίκην ριπιδίου
Abstract
dc:descriptionBackground: Controversy exists for the optimal method of internal fixation in femoral neck fractures. Biomechanical data suggest that calcar fixation is superior to central screws placement. We propose a divergent technique for placing 3 cannulated stainless steel screws engaging the calcar femorale. Methods: 52 consecutive patients admitted to our institution for a femoral neck fracture were treated with the divergent screw technique, over a seven year period. 4 patients were dead and 4 were lost to follow up. From the remaining 44 patients there were 10 males and 34 females, 33 to 78 years old (mean, 58 years). All patients were operated on by the same surgeon and were followed up for a minimum of two years (mean: 33.6 months, range: 2-6 years). Twenty- four patients sustained a non-displaced fracture (Garden I-II) and 20 a displaced fracture (Garden III-IV) of the femoral neck. Those patients were compared to a control group matched for age and Garden stage. We also tried to validate the results of the clinical analysis, using a Finite Element Model. We created a finite element mesh of femoral bone and screws which was tested for 400 material properties. The femur was embedded in the bottom part and a 70o virtual osteotomy was replicated. The fracture was fixed using either 3 parallel or 3 divergent stainless steel screws and then the femoral head was subjected to loading. Results: Mean Harris Hip Score (HHS) was 89.6 points. Avascular necrosis was evident in 4 patients (9%) with displaced fractures. Non-unions or failed internal fixation were not encountered. There was a significant difference in the HHS, in favor of the divergent group (p: 0.006), while more complications were encountered in the parallel group including six cases with non-union. Finite Element Analysis showed less propensity for displacement in the divergent group along with bigger stresses on the calcar area and more even stress distribution on the screws, while in the parallel configuration bigger deformation of the hardware was encountered. Conclusions: Parallel screw placement is not critical for an excellent clinical outcome. Our proposed technique using 3 cancellous screws that diverge in the coronal plane (one engaging the calcar femorale) may offer enhanced fixation. Finite element analysis also suggested a possible biomechanical advantage of the divergent configuration.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Παπαναστασίου, Ιωάννης
- Papanastassiou, Ioannis
Subjects
dc:subject × 16- Υποκεφαλικό κάταγμα μηριαίου
- Οστεοσύνθεση
- Αυλοφόροι κοχλίες
- Αποκλίνοντες
- Παράλληλοι
- Ανάλυση πεπερασμένων στοιχείων
- Femoral neck fracture
- Internal fixation
- Cannulated screws
- Divergent
- Parallel
- Finite element analysis
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/27932