Back to search

University of Patras

Διάδοση υπερήχων σε σπογγώδες οστούν in vitro. Eπίδραση των μεταβολών της μικροδομής στην σκέδαση των υπερήχων σ’ ένα πειραματικό μοντέλο οστεοπόρωσης

Abstract

dc:description

Ultrasound is currently being assessed as an alternative method of evaluating bone quality, and provides information about structure in addition to density. Ultrasound velocity and broadband ultrasound attenuation (BUA) determination has been explorer as an alternative method for estimating bone density and osteopososis. An other approach is the ultrasound scattering which inform us for the quality and architecture of the bone. Two different approaches have been proposed to model backscattering from cancellous bone. A first approach with discrete homogeneites use the analytical model of Faran which provides an exact solution of the backscatter cross section by a spherical or a cylindrical solid elastic object, to describe the interaction of trabecular bone with the ultrasonic wave. The second approach is based on Cernov’s proof that scattering is proportional to the product of the mean compressibility fluctuation and the autocorrelation function integrated over volume. A combination of the two autocorrelation functions was required to closely approximate the backscatter from bovine cancellous bone. The main limitations of the model are the following : • Weak scattering • The assumption of statistical homogeneity over one sample • First order multiple scattering • They do not account for shear waves in the scatterers The main limitations are satisfied from the experimental data Two simple scattering autocorrelation functions have been utilized to describe the microscopic structure of the random inhomogeneous medium: A modified Gaussian model has been considered to account for a large volume fraction of scatterers in the medium, the fluctuation in density and compressibility about the mean value, and the spherical distribution model because a number of larger plate-like scatterers with ellipsoid or roughly spherical shape may contribute to a portion of the scattering. The frequency dependence of the backscatter coefficient from bovine trabecular bone could not be discribed accurately either by scattering from a collection of randomly distributed identical scatterers or by a continuous model with a single dominant correlation length. This could be due to the tremendous variation in microarchitecture encountered in bovine trabecular bone. A combination of models was required to approximate the experimental data. The inverse problem to estimate the trabecular thickness of bone tissues has been addressed in this thesis. The estimates of correlation lengths from the combination of the two models were compared to trabecular thickness. Mean values of trabecular thickness display very large variation at both intraspecimen and interspecimen levels and cannot be used as estimates of the correlation length α. A significant contribution of this work is that interpretation of the correlation length was the dominant trabecular thickness, obtained from distribution graphs for each specimen. Significant linear correlation was found between predicted correlation length and measured trabecular thickness (R2=0.8558). In this study, it was found that the total attenuation by tissues is largely due to scattering processes than the attenuation due to absorption and the frequency dependence of attenuation due to scattering is linear for a densely populated distribution of scatterers from 100 to 600 μm, which have been measured in bovine cancellous bone, and in the range of frequencies 0.3-0.9 MHz. In the second part of this study a new experimental model was developed in order to simulate osteoporosis. Osteoporosis is a condition of reduced mass and density, change of bone 3D structure and increased fragility with a more pronounced effect on cancellous bone. Our purpose is the study of the ultrasonic frequency-depedent backscatter in dense bovine trabecular bone and the determination of a weak scattering model for the trabecular thickness which is relative to osteoporosis. The simulation of osteoporosis was developed in order to evaluate the effects of change of mineral content and microstructure on ultrasonic properties of cancellous bone with immersion in hydrocloric acid. Timed immersion in hydrochloric acid was used to selectively alter the mineral content. Scanning electron microscopy and histological staining of the acid-treated trabecular demonstrated a heterogeneous structure consisting of a mineralized core and a demineralized layer. Τhe accuracy of estimation was found to increase with trabcular thickness. A two-component model of weak scattering utilizing a combination of two autocorrelation functions (a densely populated model and a spherical distribution) to evaluate the trabecular thickness in various stages of decalcification. Τhe accuracy of estimation was found to increase with trabcular thickness.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Apostolopoulos, Konstantinos
  • Αποστολόπουλος, Κωνσταντίνος

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/28013

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Apostolopoulos, Konstantinos; Αποστολόπουλος, Κωνσταντίνος. Διάδοση υπερήχων σε σπογγώδες οστούν in vitro. Eπίδραση των μεταβολών της μικροδομής στην σκέδαση των υπερήχων σ’ ένα πειραματικό μοντέλο οστεοπόρωσης. University of Patras, 2009. http://hdl.handle.net/10442/hedi/28013