Ανάπτυξη νέων μεθόδων προσδιορισμού ολικής αντιοξειδωτικής ενεργότητας και εφαρμογή στο ελαιόλαδο

Abstract

dc:description

The automation of analytical methods is very important as a large analytical batch can be processed with accuracy, in short time, while the human intervention is minimized. Flow injection (FI) and the newer sequential injection (SI) analysis are the most applicable automation techniques. They incorporate the technological development in both microdevices and microcomputers. The frequency of measurements is increased, data are taken directly and the consumption of reagents is minimized. The FI and SI analyzers are easy in use, portable and have low cost. In this thesis, novel automated methods for olive oil total antioxidant capacity (TAC) assessment, based on flow and sequential injection techniques, were developed: I. High throughput bioluminometric method (chapter 5): The chemistry involved was the horseradish peroxidase (HRP) catalysed oxidation of luminol by hydrogen peroxide. Oxidation results in light emission (bioluminescence) that is enhanced using p-iodophenol sensitizer. Αliquot of the olive oil extract containing hydrophilic antioxidants was merged with a luminol – HRP – p-iodophenol reagent stream. Bioluminescence resulting after merging the mixture with a hydrogen peroxide stream was suppressed upon increasing antioxidants’ concentration resulting in negative peaks due to hydrogen peroxide consumption by antioxidants. The method has been optimized on: 1) number of manifold channels, 2) flow rates, 3) coil length and 4) HRP, hydrogen peroxide and p-iodophenol concentrations, in a laboratory made analyzer. Detection limit was calculated at 13 10-6 M gallic acid equivalent, limit of quantification was 43 10-6 M gallic acid equivalent, linear range was between 1.0 10-6 and 1 10-4 M and intra laboratory precision was better than 2.8% RSD (n=4). The method is fully automated achieving a sampling rate of 180 per hour. II. High throughput sequential injection method for FRAP assessment (chapter 6): The FRAP assay that measures the ability of the antioxidant to reduce the ferric 2,4,6-tripyridyl-s-triazine salt (Fe(III) – TPTZ) to the blue colored ferrous complex (Fe(II) – TPTZ) at pH 3.6, was modified and automated in a SI system. The method has been optimized for Fe(III) and TPTZ concentration, injection volume of methanolic extract and flow rate. The proposed method was validated in terms of detection limit, linearity, repeatability and reproducibility. Detection limit was 0.89 μmol equiv. FeSO4 g-1. Linear range was 0.01-0.2 mM, r=0.9995. The relative standard deviation (RSD %) of repeatability and reproducibility were 0.79% (n=54) and 3.6% (n=3) respectively, while a sampling rate of 90 per hour was achieved. Antioxidant activities estimated by the automated method were in the range of 24.7-1162 μmol equiv. FeSO4 g-1 for olive oil samples and 2.8 - 5.8 μmol equiv. FeSO4 g-1 for sunflower, soya, corn and sesame oil. Results indicated that olive oil had the highest antioxidant content while sesame, corn, soya and sunflower oils are following with lower values. During the analysis of 54 edible oil samples, the developed SI method was compared and correlated well with the FRAP assay, using a paired t-test method. The proposed methods offer several advantages:  Low detection limits were achieved.  Short analysis time.  Simplicity: the proposed methods are simple to perform.  Repeatability and reproducibility  Analytical throughput.  Low cost portable apparatus.  Low reagent and sample consumption. The DPPH, ABTS and Folin-Ciocalteu methods were modified and applied for olive oil TAC and TPC assessment (chapter 7). The developed methods were compared during the analysis of a total of 50 extra virgin olive oil samples from different Greek regions and cultivars. Antioxidant capacities were determined in the methanolic olive oil extract and total fraction using the DPPH method. This method was modified in terms of the DPPH radical concentration (13 mM in advanced of 20 mM using in original method) and the final sample/DPPH working solution ratios. In addition, incubation time was increased at 1 hour for the completion of antioxidant and DPPH radical reaction. Antioxidant capacities in methanolic extracts were found between 1.29 and 9.95 mM equiv. of gallic acid Kg-1 olive oil, while in olive oil, TAC was between 77 and 177 mM mM equiv. of gallic acid Kg-1 olive oil. Calibration curves acquired for all olive oil samples were linear (correlation coefficients: 0.98-1.000). Precision ranged between 2.2 and 3.5 % RSD for the total fraction method and 7.0 and 9.9 % RSD for the method acquired in methanolic extract. The ABTS method was modified using hydrogen peroxide as oxidant instead of persulfate potassium, and horseradise peroxidase (HRP) enzyme as catalyst for the ABTS radical formation reaction. Three hours were required for the ABTS radical formation reaction. After reaction completion, the volumetric flask was filled with methanol. Final methanol concentration in ABTS●+ solution was 80% (v/v). This working solution was mixed with methanolic olive oil extract completely. Antioxidant capacities determined in the methanolic olive oil extract were between 5.42 – 22.5 mM equiv. of gallic acid Kg-1 olive oil. Calibration curves acquired for all olive oil samples were linear (correlation coefficients: 0.99-1.000). Precision ranged between 6.9 and 9.7 % RSD. The total phenol content was determined in methanolic olive oil fraction using the Folin-Ciocalteu method, that was found between 3.80 and 29.4 mM equiv. of gallic acid Kg-1 olive oil. The method was modified in terms of the time measurement of samples-folin reagent mixtures. Mixtures were stored in the dark for 2 hours instead of 24 hours as in manually FRAP method. Precision ranged between 6.4 and 8.8 % RSD. Total phenol content correlates with total antioxidant capacity assessed in hydrophilic fraction through the DPPH (r=0.89) and the ABTS (r=0.69) assays. The methanolic extract DPPH values correlate significantly with the ABTS values (r=0.81). However, the DPPH values for total olive oil correlate poorly with the ABTS assay, the Folin-Ciocalteu method and the DPPH assay in methanolic extract. Total phenols content shows good correlation with ABTS and DPPH values and could serve as a useful indicator for olive oil antioxidant capacity. A multi-element analysis of virgin olive oil samples from different regions and cultivars was carried out by inductively coupled plasma mass spectrometry (ICP-MS) aiming at mapping Greek olive oil and checking the probable correlation of results from multi-element analysis with TAC values (chapter 8). Data were processed by means of the chemo metric approach of Principal Component Analysis (PCA) that allows classifying unknown samples after checking possible differentiation of samples of known origin and cultivar. For the quantitative analysis, standard solutions were prepared by diluting multi-element solutions of 89Y, 111Cd, 118Sn, 139La, 141Pr, 152Sm, 153Eu, 164Dy, 166Er isotopes (Group A, 10 μg L-1) and of 25Mg, 55Mn, 57Fe, 60Ni, 66Zn, 88Sr isotopes (Group B, 100 μg L-1) The calibration range for the elements of Group A was from 1 to 100 ng L-1and for Group B was from 0.1 to 100 μg L-1. In and Ge were used as internal standards, respectively. The correlation coefficients of calibration curves were between 0.997 and 0.99998 for all elements. The isotopes 89Y, 111Cd, 118Sn, 139La, 141Pr, 152Sm, 153Eu, 164Dy, 166Er were present in samples in lower amounts than 25Mg, 55Mn, 57Fe, 60Ni, 66Zn, 88Sr. Results from recovery experiments were in the range of 92 (166Er) – 118% (57Fe). Furthermore, limits of quantification, LoQs, were in the range of 0.011 (166Er) - 0.61 (118Sn) μg L-1 for Group A elements and 0.73 (55Mn) – 420 (57Fe) μg L-1 for Group B elements. Sensitivity and reproducibility of analytical procedure, including the digestion pre-treatment of samples, were also determined. The relative standard deviation was between 0.8 (153Eu) and 9% (25Mg). For the principal component analysis 7 elements (25Mg, 57Fe, 66Zn, 139La, 141Pr, 153Eu and 166Er) were selected to differentiate extra virgin olive oils according to region and cultivar. Although trace element content did not correlate well with TAC values, the results obtained were a map of the trace element content of Greek olive oils during the analysis by this simple and rapid ICP-MS method.

Degree

thesis:*
Grantor dc:publisher
Agricultural University of Athens
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Μηνιώτη, Αικατερίνη
  • Minioti, Katerina

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/28105

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Μηνιώτη, Αικατερίνη; Minioti, Katerina. Ανάπτυξη νέων μεθόδων προσδιορισμού ολικής αντιοξειδωτικής ενεργότητας και εφαρμογή στο ελαιόλαδο. Agricultural University of Athens, 2009. http://hdl.handle.net/10442/hedi/28105