National and Kapodistrian University of Athens
Orthodontic mini-implants: morphological/structure characteristics and in vivo performance in animals
Abstract
dc:descriptionThe purpose of this study was to investigate the geometrical characteristics, composition, microstructure, surface roughness, stress generation and distribution, and pullout strength of commercially available orthodontic mini-implants (OMIs). In order to investigate the possible association of the findings and their clinical significance, four different OMIs systems were placed in early preadolescent pigs. Histomorphometric analysis of the periimplant bone area will be performed after two weeks time. The OMIs systems evaluated were AbsoAnchor® (AA), Dual-Top™ (DT), Spider Screws® K1 (SK), and Vector-TAS™ (VT). The geometrical features of the OMIs were measured by optical microscopy. Surface texture and elemental composition were examined by SEM and energy dispersive X-ray microanalysis. Surface 3D-roughness parameters were measured by optical profilometry. The pullout strength was measured using a universal testing machine. Stress generation and distribution was estimated around OMIs using photoelastic resin.The biological performance of OMIs was tested using an animal model implanted with 48 OMIs (n: 3x4 brands/pig). Two weeks later, the stability and success rate were assessed. Specimens consisted of an OMI and its surrounding bone was retrieved from the animals. Longitudinal 1mm sections were obtained. Then the sections were grounded and polished. Histomorphometric analysis was performed in unstained sections, bone-implant contact (BIC) was measured and percentage of osseointegration was calculated. The following conclusions can be drawn from the study:•All the OMIs tested were homogeneous in structure, based on Ti6Al4V alloy, with N impurities. VT had the highest O and P content, implying an anodic oxidized surface.•AA demonstrated the highest intra-osseous surface. •No statistically significant differences were detected in amplitude surface roughness parameters (Sa, Sz) among the implants. However, differences existed in hybrid (Sdr, Sds) and functional (Sci) parameters. •AA achieved the highest pullout strength in both artificial bone densities followed by DT, SK and VT with higher value in higher bone density. •Without pilot drill preparation, all OMIs showed high stress generation represented by third order fringe. SK exhibited the greater stress distribution surrounding the neck area. At the mid intra-osseous region, VT had the greater stress distribution. •Stress with pilot drill preparation, pilot drilling reduced stress generation and AA and DT showed stress generation represented by second order fringe, while SK stress generation represented by first order fringe. •Under horizontal loading, the stress distribution was shifted toward the direction of acting forces.•In contrast to in vitro data, no significant differences in OMIs survival rates were encountered in vivo. Overall, the success rate was quite low (45.8%). The differences detected in implant morphological and structural characteristics did not seem to affect survival rate. •Immediate loading and palatal placement of OMIs were ineffective when used in early preadolescent pigs. Anterior placement enhanced the success rate. •The overall percentage of osseointegration was estimated as 31.2%. No difference was detected in the BIC area between the maxilla and the mandible.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Samak, Saeed
Subjects
dc:subject × 16- Ορθοδοντικά μικροεμφυτεύματα
- Δύναμη έλξης
- Επιφανειακή αδρότητα
- Ηλεκτρονικό μικροσκόπιο σάρωσης
- Ανάλυση τάσεων
- Επιφάνεια επαφής μικροεμφυτεύματος-οστού
- Orthodontic mini implant
- Pull out strength
- Surface roughness
- Scanning electron microscope
- Stress analysis
- Bine implant contact
- Ιατρική και Επιστήμες Υγείας
- Βασική Ιατρική
- Medical and Health Sciences
- Basic Medicine
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/28262