Orthodontic mini-implants: morphological/structure characteristics and in vivo performance in animals

Abstract

dc:description

The purpose of this study was to investigate the geometrical characteristics, composition, microstructure, surface roughness, stress generation and distribution, and pullout strength of commercially available orthodontic mini-implants (OMIs). In order to investigate the possible association of the findings and their clinical significance, four different OMIs systems were placed in early preadolescent pigs. Histomorphometric analysis of the periimplant bone area will be performed after two weeks time. The OMIs systems evaluated were AbsoAnchor® (AA), Dual-Top™ (DT), Spider Screws® K1 (SK), and Vector-TAS™ (VT). The geometrical features of the OMIs were measured by optical microscopy. Surface texture and elemental composition were examined by SEM and energy dispersive X-ray microanalysis. Surface 3D-roughness parameters were measured by optical profilometry. The pullout strength was measured using a universal testing machine. Stress generation and distribution was estimated around OMIs using photoelastic resin.The biological performance of OMIs was tested using an animal model implanted with 48 OMIs (n: 3x4 brands/pig). Two weeks later, the stability and success rate were assessed. Specimens consisted of an OMI and its surrounding bone was retrieved from the animals. Longitudinal 1mm sections were obtained. Then the sections were grounded and polished. Histomorphometric analysis was performed in unstained sections, bone-implant contact (BIC) was measured and percentage of osseointegration was calculated. The following conclusions can be drawn from the study:•All the OMIs tested were homogeneous in structure, based on Ti6Al4V alloy, with N impurities. VT had the highest O and P content, implying an anodic oxidized surface.•AA demonstrated the highest intra-osseous surface. •No statistically significant differences were detected in amplitude surface roughness parameters (Sa, Sz) among the implants. However, differences existed in hybrid (Sdr, Sds) and functional (Sci) parameters. •AA achieved the highest pullout strength in both artificial bone densities followed by DT, SK and VT with higher value in higher bone density. •Without pilot drill preparation, all OMIs showed high stress generation represented by third order fringe. SK exhibited the greater stress distribution surrounding the neck area. At the mid intra-osseous region, VT had the greater stress distribution. •Stress with pilot drill preparation, pilot drilling reduced stress generation and AA and DT showed stress generation represented by second order fringe, while SK stress generation represented by first order fringe. •Under horizontal loading, the stress distribution was shifted toward the direction of acting forces.•In contrast to in vitro data, no significant differences in OMIs survival rates were encountered in vivo. Overall, the success rate was quite low (45.8%). The differences detected in implant morphological and structural characteristics did not seem to affect survival rate. •Immediate loading and palatal placement of OMIs were ineffective when used in early preadolescent pigs. Anterior placement enhanced the success rate. •The overall percentage of osseointegration was estimated as 31.2%. No difference was detected in the BIC area between the maxilla and the mandible.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Samak, Saeed

Subjects

dc:subject × 16

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/28262

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Samak, Saeed. Orthodontic mini-implants: morphological/structure characteristics and in vivo performance in animals. National and Kapodistrian University of Athens, 2011. http://hdl.handle.net/10442/hedi/28262