National Technical University of Athens (NTUA)
Διηλεκτρικά και θερμικά φαινόμενα σε γραμμές μεταφοράς και διανομής
Abstract
dc:descriptionThis thesis investigates the dielectric and thermal phenomena in transmission and distribution lines, which manifest during their steady-state or transient operation. An introduction to transmission and distribution networks is made in the first chapter. Specifically, a brief presentation of the thermal and dielectric phenomena manifesting in overhead and underground lines is made. The aim of this thesis is: the development of a model for the calculation of the open conductor effects (phase or neutral conductor) and the proposal of a protection method for the mitigation of the aforementioned effects, the development of a mathematical model for the calculation of the thermal effect of the recloser operation cycle on conductors. and the experimental investigation of the dielectric behavior of transformer oil after the transformer transportation to its installation point. Chapter 2 develops a mathematical model for the calculation of the open conductor effects (phase or neutral conductor). Additionally, protection methods are presented for the mitigation of said effects. Chapter 3 develops a novel model for the calculation of the thermal effect of the recloser operation cycle on conductors. Chapter 4 develops a novel ladder network for wooden poles and verifies it through Finite Element Analysis. Chapter 5 presents a power flow algorithm for four-wire distribution systems with an abrupted multiply-grounded conductor. Finally, chapter 6 presents the results of the experimental investigation of the dielectric behavior of transformer oil after the transformer transportation to its installation point. Within the framework of this thesis, three computer programs have been developed in order to facilitate the calculations and the extraction of conclusions. The programs are: program for the calculation of the short-circuit thermal effect on transmission conductors, program for the calculation of the thermal effect of the recloser operation cycle on conductors, program for the calculation of the conductor temperature rise during a fire, program for the calculation of transmission and distribution line conductor sag. Discussion of the experimental and theoretical results is made in chapter 7 Specifically, the abruption and fall to the ground of a phase conductor can lead to a fire, whilst the abruption of the neutral conductor leads to neutral shift downstream of the abruption point and to voltage sags and swells. The mechanical stressing of the transformer oil leads to decreased breakdown strength. Finally, the developed mathematical model for the calculation of the thermal effect of the recloser operation cycle on conductors can be used to assess the conductor ability to withstand faults. The eight chapter presents the contribution of this thesis to further research as well as practical applications.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Halevidis, Constantinos
- Χαλεβίδης, Κωνσταντίνος
Subjects
dc:subject × 14- Γραμμές μεταφοράς
- Γραμμές διανομής
- Θερμικά φαινόμενα
- Διηλεκτρικά φαινόμενα
- Σύστημα γειώσεως
- Transmission lines
- Distribution lines
- Thermal phenomena
- Dielectric phenomena
- Earthing system
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Mechanical Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/28661