Παράγοντες που επηρεάζουν την αξιοπιστία της μέτρησης της αρτηριακής πίεσης με ταλαντωσιμετρική τεχνική

Abstract

dc:description

INTRODUCTION: Oscillometric devices are being widely used for ambulatory, home and office blood pressure (BP) measurement and many of them have been successfully validated using established protocols. However, even successfully validated devices fail to provide accurate measurements in some patients. Given the trend for mercury use elimination due to its toxicity, the limitation in reliability of oscillometric devices should be further investigated. AIM OF STUDY: A) to assess the prevalence, reproducibility and characteristics of the phenomenon of unreliable oscillometric BP (UOBP) measurements and B) to assess the impact of replacing the mercury sphygmomanometer by a validated professional oscillometric device on treatment decisions in hypertension. PATIENTS - METHODS: Consecutive patients attending a hypertension clinic within 14 months, had triplicate simultaneous BP measurements using a mercury sphygmomanometer and a validated professional oscillometric device (BpTRU). UOBP readings were defined as those with BP difference >10 mm Hg (systolic and/or diastolic) between the two methods. Patients with persistent UOBP were detected and compared with a control group. RESULTS: A) Analysis was based on 1.706 visits of 755 patients (a total of 5.070 measurements). UOBP was found in 15% of systolic BP (SBP) and 6.4% of diastolic (DBP) measurements. 18% of patients had disagreement regarding the UOBP presence between their first and second study visit. However, 49% of them had at least one additional UOBP visit during the study. Patients with persistent UOBP were more likely to be female and had lower arm circumference. The systolic BP discrepancy between the two methods was associated with pulse pressure (r=0.41) and inversely with diastolic BP (r=0.40) and arm circumference (r=0.30), whereas the diastolic discrepancy with diastolic BP (r=0.61) and inversely with pulse pressure (r=0.32). There was a consistent and significant trend towards larger systolic BP discrepancy and smaller diastolic from the lower to the higher pulse pressure quintile (P=0.0001). A decreasing arm circumference was a significant predictor of persistent UOBP. B) Analysis was based on 1.717 visits of 763 patients (a total of 5.108 BP measurements). In 24% of visits, the two methods led to different conclusions regarding the diagnosis of uncontrolled hypertension. In 4.9% of visits, the diagnostic disagreement was considered as “clinically important” (BP exceeding the diagnostic threshold by ≥5 mmHg). CONCLUSION: These data suggest that the UOBP phenomenon is particularly common, not very reproducible and mainly affected by pulse pressure and arm circumference. They also suggest that replacement of the mercury sphygmomanometer with a validated professional oscillometric device would result in a different decision regarding antihypertensive treatment in 5% of cases. Further technological development is required and caution is needed when using oscillometric devices in patients with arterial stiffness.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Lourida, Panagiota
  • Λουρίδα, Παναγιώτα

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/28674

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Lourida, Panagiota; Λουρίδα, Παναγιώτα. Παράγοντες που επηρεάζουν την αξιοπιστία της μέτρησης της αρτηριακής πίεσης με ταλαντωσιμετρική τεχνική. National and Kapodistrian University of Athens, 2013. http://hdl.handle.net/10442/hedi/28674