Abstract
dc:descriptionPurposeThe purpose of this study was to quantify the dose perturbation in a low atomic number tissue, before an interface of high atomic number and density material, during irradiation with high energy photons.Materials and MethodsA Plexiglas phantom was used as well as inhomogeneities made of aluminum, copper, lead and steel. Dose measurements were carried out using radiochromic films (HD-810 and MD-55, ISP manufactured). Irradiations were performed in a Co-60 unit and a 6 MV linear accelerator. The dosimetric characteristics of films were studied and compared for doses up to 500 Gy in water using the hp scanjet 4570c series digital flatbed scanner. As a measure of the absorbed dose perturbation into a material of low atomic number, in the presence of high atomic number inhomogeneities at the entrance point of the beam, the quantity Backscatter Dose Factor (BSDF) was used. ResultsThe dependence of OD on the absorbed dose in water, for both film types, was described by a 2nd order polynomial function (transmission method); the dependence of the readings for the reflection pixels was adjusted with logarithmic curves. The dynamic dose range of the reflection method is larger than that of the transmission method for the red component. In addition, measurements of doses lower than 16.9 Gy are more accurate if the reflection method is used. The use of all three color components allows for the extension of the dynamic range of MD-55 films to doses up to at least 500 Gy. Additionally, it was found that approximetaly 25 minutes are required for the scanner to stabilize in order to provide reliable readings when the transmission mode was used. It was also found that if the time interval between irradiation and measurement is greater than 4 days then it is essential to apply dose-dependent correction factors.It was found that BSDF: a) varies with the square root of the atomic number of the inhomogeneity, b) increases as the thickness of the inhomogeneity increases (up to a saturation thickness), c) decreases by increasing photon energy at short distances from the interface, d) decreases by increasing the angle of irradiation, e) can be considered practically independent of the depth at which the inhomogeneity is placed (with the condition that the placing depth is greater than the build-up for each energy) and f) depends on photon field size only in small fields close to a Pb inhomogeneity at short distances from the interface.ConclusionsTwo alternative simple, low cost and accurate reading methodologies of radiochromic films were developed and employed using a document scanner. Empirical equations where derived, which correlate BSDF with the irradiation conditions and could be used to improve the dose distribution calculations in teletherapy when a high atomic number inhomogeneity is found in the beam path.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Karava, Konstantina
- Καραβά, Κωνσταντίνα
Subjects
dc:subject × 23- Δοσιμετρία
- Ανομοιογένειες υψηλού ατομικού αριθμού
- Ακτινοθεραπεία
- Φωτόνια
- Ραδιοχρωμικά φιλμ
- Σαρωτής διαταραχής δόσης
- Ποιοτικός έλεγχος σαρωτή
- Dosimetry
- High atomic number inhomogeneities
- Radiotherapy
- Photons
- Radiochromic film
- Document scanner
- Dose perturbation factor
- Evaluation of the document scanner
- Φυσικές Επιστήμες
- Φυσική
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Natural Sciences
- Physical Sciences
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/29037