National Technical University of Athens (NTUA)
Παραγωγή ενέργειας με αεριοποίηση ιλύων από μονάδες βιολογικών καθαρισμών
Abstract
dc:descriptionThe process of the activated sludge is commonly used in the aerobic wastewater treatment plants. The initial BOD content of the influent is mainly transformed into biological sludge, which is considered to be secondary pollution. A new, most promising method for sludge energy utilization is gasification. The present study focuses on the impact of the Θc on the net energy production through gasification of waste activated sludge. Waste activated sludge samples of every distinctive Θc =1 to 30d were produced and analyzed both quantitatively and qualitatively. The sludge samples were fed to an allothermal bench scale batch gasifier and the solid residues (char), the gaseous products (CO2, H2, CO, CH4) and the tar byproduct were quantitatively and qualitatively analyzed. The results were evaluated with assessment models of the energy efficiency in comparison with the heating value of the sludge sample and were reduced based on the carbon mass content of the influent, in order to obtain comparable quantitative results on the energy efficiency and the imposed Θc. Net energy calculations were made by the deduction of the corresponding energy production form gasification to the energy consumption of the wastewater treatment plant. From the results it was concluded that the increase of Θc resulted in the increase of ash content and decrease of the lower heating value of the sludge produced. The sludge composition, according to the Van Krevelen diagram, placed the sludge produced in an uncharted territory far from the common solid fuels. Gasification efficiency presented a slight but steady rate of increase with the Θc=30d. On the contrary, the total energy produced per gram of carbon in the influent of the biological system was constantly reduced. The energy balance from the combination of the energy utilization of the sludge and the energy requirements of an WWTP was proved positive for Θc=1 to 8d.The present study proves that the combined biological and thermal unit operates with higher energy efficiencies at lower Θc. Furthermore, gasification of the activated sludge is a most promising method for its utilization and disposal.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Stamatoglou, Aimilios
- Σταματόγλου, Αιμίλιος
Subjects
dc:subject × 16Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/29188