University of Thessaly (UTH)
Οφθαλμική ελαστικότητα και αιματική ροή σε φυσιολογικούς και γλαυκωματικούς οφθαλμούς
Abstract
dc:descriptionThe purpose of the first study is to investigate the relation between axial length (AL), as a surrogate parameter for ocular volume, and ocular rigidity (OR), ocular pulse amplitude (OPA) and pulsatile ocular blood flow (POBF). In the second study, we compare OR and outflow facility (C) coefficients in medically treated open angle glaucoma (OAG) patients and controls and investigate differences in ocular pulse amplitude (OPA) and pulsatile ocular blood flow (POBF) between the two groups.Eighty eight cataract patients participated in the first study. In the second study, twenty one patients diagnosed with early or moderate primary or pseudoexfoliative OAG and 21 controls were enrolled. The measurements were performed intraoperatively with the use of a computer controlled device, comprising a microdosimetric pump and a pressure sensor. After cannulation of the anterior chamber, the system is used to raise the intraocular pressure (IOP) from 15 to 40 mmHg, by infusing the eye with a saline solution. The IOP is continuously recorded for 2 seconds after each infusion step. At an IOP of 40mmHg, an IOP decay curve was recorded for four minutes. Blood pressure and pulse rate were measured during the procedure. OR coefficients, OPA and POBF were estimated from IOP and volume recordings. C was calculated from the outflow curve data.In the first study, median AL was 23.69 (IQR 3.53) mm. The OR coefficient was 0.0218 (0.0053) μl-1 and was negatively correlated with AL (ρ=-0.641, p=<0.001). Increasing AL was associated with decreased OPA (ρ=-0.637, p=<0.001 and ρ=-0.690, p=<0.001) and POBF (ρ=-0.207, p=0.053 and ρ=-0.238, p=0.028) at baseline and elevated IOP respectively. In the second study, there were no differences in age or AL in the two groups. The OR coefficient was 0.02200.0053 μl-1 in the OAG and 0.02220.0039 μl-1 in the control group (p=0.868). C was 0.0920.082 μl/min/mmHg in the glaucoma group compared to 0.1490.085 μl/min/mmHg in the control group at an IOP of 35 mmHg (p<0.001) and 0.1780.133 μl/min/mmHg versus 0.2920.166 μl/min/mmHg respectively at an IOP of 25mmHg (p<0.001). No differences in OPA or POBF were found between the two groups at baseline and increased levels of IOP (p>0.05).Ocular volume is a parameter that strongly affects OR. POBF calculated with the use of the OR coefficient, measured in each eye, is reduced in high myopia, especially in elevated levels of IOP. These findings suggest decreased pulsatility in high myopia and may influence ocular pulse studies.Moreover, manometric data reveal lower C values in OAG patients. The OR coefficient, OPA and POBF did not differ between medically treated OAG patients and controls, failing to provide evidence of altered scleral distensibility and choroidal blood flow in OAG.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Dastiridou, Anna
- Δαστιρίδου, Άννα
Subjects
dc:subject × 18- Οφθαλμική ελαστικότητα
- Οφθαλμικό εύρος παλμού
- Ευχέρεια εκροής
- Οφθαλμική αιματική ροή
- Γλαύκωμα ανοιχτής γωνίας
- Αξονικό μήκος
- Οφθαλμολογία
- Ocular rigidity
- Ocular pulse amplitube
- Ocular blood flow
- Outflow facility
- Open angle glaucoma
- Axial length
- Opthalmology
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/29437