Back to search

National Technical University of Athens (NTUA)

Αλληλεπίδραση ακτινοβολίας λέιζερ και οργανικών υλικών με εφαρμογές σε μικρο – αισθητήρες

Abstract

dc:description

In this PhD Thesis the interaction of nanosecond laser pulses with organic materials was investigated for the selective deposition of micro-patterns with a high spatial resolution. The selective deposition of the materials was carried out by using a novel laser printing technique named Laser Induced Forward Transfer (LIFT). LIFT was employed for studding micro-deposition of model organic solutions and wetting state transitions of rough surfaces. The technique was also applied for the development of three different types of micro-sensors. At the first part of this study, selective deposition of micro-droplets was investigated and optimized by using glycerol based organic solutions of different viscosity. The viscosity of the glycerol based solutions was varied from 1.2 mPa s to 8.5 mPa. As the viscosity of the solutions is increased there is an increase to laser threshold fluence which is needed for the droplets ejection. The laser threshold energy for droplets ejection was defined to be 100 mJ/cm2 200 mJ/cm2 and 260 mJ/cm2 for viscosity values of 1.2 mPa s, 3.2 mPa s and 8.5 mPa s, respectively. The increase of the viscosity of the solutions resulted in an increase to the effective range of laser fluence, which could be defined as the laser fluence range that leads to the deposition of uniform droplets. The effective laser fluence range was found to be 320 mJ/cm2 - 520 mJ/cm2 and 410 mJ/cm2 - 975 mJ/cm2 for viscosity values of 3.2 mPa s and 8.5 mPa s, respectively. Optical microscopy characterization has shown that the diameter of the deposited droplets could be ranged from 70 μm to 160 μm (volume range 1pL to 33 pL) by using a laser spot size of 30 μm. The use of LIFT for the deposition of liquid biomaterial droplets onto rough receiving substrates revealed the possibility of decreasing the contact angle of the droplets compared to conventional printing techniques. A wetting phase transition from a partial wetting state (89.4ο, conventional pipette printing) to a complete wetting state (18.5ο, LIFT) was observed for the deposition of biomaterial droplets onto a rough receiving electrode with laser pulse energy larger than 275 mJ/cm2. The effect takes place due to the high velocity transfer (100 m/s – 200 m/s) of the liquid droplets onto the receiving substrate and could not be reproduced by conventional printing techniques. The mechanism of the droplets deposition is based on the formation of a high velocity liquid jet (10 m/s – 300 m/s) that induces a high wetting pressure onto the surface of the electrode. The wetting pressure was calculated to be 0.3 MPa for low velocity transfer (25 m/s) at 125 mJ/cm2 and 11 MPa for high velocity transfer (150 m/s) at 350 mJ/cm2. A wetting pressure of 5.8 MPa (275 mJ/cm2) was found to be the threshold for the transition to a complete wetting state of the surface. Chemical micro-sensors were developed by using LIFT for the selective deposition of polymer layers (PHEMA, PAA and P4VP) onto the sensing sites (silicon membranes) of a capacitive micromechanical sensor. The diameter of the laser printed polymer layers was ranged from 30 μm to 200 μm for a laser spot size of 30 μm. The flexibility of the technique enabled partial coverage of the membranes with the polymer materials. The normalized response of the sensor to water vapour revealed that a partial coverage of 70 % percent optimizes its sensitivity. Following this result, chemical sensors were developed by LIFT and characterized for the detection of water and ethanol vapour for a concentration range from 5000 ppm to 20000 ppm. Biological micro-sensors were developed by using the LIFT technique for the deposition of oligonucleotides related to the b-thalassaimia disease onto of the capacitive micromechanical sensor. The sensors were then used for the detection of DNA hybridization using low concentration (36 nM) PCR product. The use of LIFT for the development of a photosynthetic amperometrc biosensor revealed a significant advantage of the technology. Direct immobilization of the photosynthetic material (proteins) onto the surface of the sensors was achieved without using chemical linkers. The effect is attributed to the wetting phase transition of the rough surface of the electrode due to the LIFT process. The ejected droplets induce high impact pressure on the sensor surface, which is calculated a few MPa. This pressure is higher to the barrier which is needed in order to transit from a partial to a complete wetting state. As a result of this wetting state transition, physical adsorption of the biomaterial on the electrode surface is enhanced. The photosynthetic sensors presented high photocurrent activity (~ 320 nA) combined with and high signal to noise ratio. By using the developed sensors, two widely used pesticides (Linuron and Diuron) were detected in the nM concentration range. LIFT enabled the development of an advanced photosynthetic sensor due to the direct immobilization method that eliminates surface functionalization of the electrode. Current immobilization technologies involve the use of chemical or gels that that are usually harmful for delicate biomaterials such as photosynthetic proteins.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Boutopoulos, Christos
  • Μπουτόπουλος, Χρήστος

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/29820

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Boutopoulos, Christos; Μπουτόπουλος, Χρήστος. Αλληλεπίδραση ακτινοβολίας λέιζερ και οργανικών υλικών με εφαρμογές σε μικρο – αισθητήρες. National Technical University of Athens (NTUA), 2011. http://hdl.handle.net/10442/hedi/29820