National and Kapodistrian University of Athens
Η συμβολή του διφασματικού δείκτη παρακολούθησης της εγκεφαλικής λειτουργίας σε καρωτιδικές ενδαρτηρεκτομές
Abstract
dc:descriptionCarotid endarterectomy (CEA) has been shown to be an effective treatment in patients with severe, symptomatic or asymptomatic, internal carotid stenosis. Intraoperative ischaemia during carotid cross-clamping is a major complication and prompt recognition of insufficient cerebral blood supply is crucial. None of the already existing forms of monitoring cerebral blood flow is believed to be the best, as none of these has 100% sensitivity or specificity. AIM: The aim of this study was to evaluate the possible correlation of Bispectral Index Monitoring (BIS) with intraoperative cerebral ischaemia in CEA under general anaesthesia. PATIENTS AND METHODS: In this study, 40 patients were included, undergoing elective CEA for both symptomatic and asymptomatic carotid artery stenosis with shunting under general anesthesia. The patients were randomly allocated to 2 groups based on the inhaled anaesthetic used for the maintenance in anaesthesia (Group A: Sevoflurane and Group B: Desflurane). Data were based on arterial pressure, heart rate and BIS values recorded at 10 different surgery time points, with special attention paid during carotid clamping. The two groups were also compared for early and late recovery. RESULTS: The mean carotid clamping time did not differ statistically between the 2 groups, with mean value in Group A:66.4 and in Group B:58,5. The mean BIS values in both groups at the recorded surgery time points were kept constant between 40-60, with the lowest mean value 46,53 one minute after the carotid clamping release. Only 2 of the total of 40 patients experienced clinical signs of cerebral ischemia. Only one of these 2 patients had a sudden BIS decrease after the carotid clamping release. Another 2 of the total of 40 patients had BIS values decrease during the recorded surgery time points, without clinical signs of cerebral ischemia. Regarding the recovery, patients in Group B (Desflurane) had faster early recovery than patients of Group A (Sevoflurane). CONCLUSION: During CEA under general anaesthesia BIS may decrease or remain unchanged in the values of 40-60. BIS decrease may indicate reduced cerebral blood 131 flow, but it can not be used as a 100% reliable indicator in CEA for early recognition of cerebral ischemia.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Προδρόμου, Χριστιάνα
- Prodromou, Christiana
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/29968