Back to search

National Technical University of Athens (NTUA)

Σχεδιασμός, κατασκευή και αξιολόγηση μονάδας θερμικής εκρόφησης προσαρμοσμένης σε gc/ms: μετρήσεις εκπνεόμενου αέρα

Abstract

dc:description

The present Ph.D. Thesis can be grouped under Analytical Chemistry and especially under the field of ambient air analysis. The basic instrumental direction of this Thesis, is the use of, widespread for decades, Gas Chromatography combined with Mass Spectrometry (GC/MS). The main objective of this Thesis was the development of an analytical method that is capable of identifying Volatile Organic Compounds (VOCs) at very low, even extreme, detection limits of few ng or even fg per L of ambient air. This resulted in the choice of VOC sampling on absorbent material and thermal desorption to a GC/MS system. Target of this Thesis was the in-house construction of a thermal desorption system and not the simple purchase and use of a commercially available one, even such systems are readily available for more than a decade. This in-house made system was connected to an existing GC/MS system and its construction served the cause of creating know-how that can be used in the future. The design was not intended to compete with commercial systems. Nevertheless, it was chosen that its specifications would not be, at least significantly, worse than that of commercial systems. Moreover the specifications complied with those requested by the United States Environmental Protection Agency.Following the construction completion, a thorough and novel set of system tests was done. These tests and the pass /fail criteria, were derived from typical analytical equipment validation procedures. Some tests also were taken out of thermal desorption system specifications such as the percentage of analyte re-focusing on the cryogenic secondary trap and the full release during thermal desorption from the sorbent tube.The system’s analytical power was used for a research project for detecting entrapped people in building ruins at the instance of an earthquake. The result was two novel applications. The first involved the identification and quantification of VOCs present in the exhaled air of healthy humans, at a concentration threshold of nmol / L.The second application of this Thesis investigated the VOC chemical fingerprint that is derived from the decomposition of the human body and especially how this is differentiated from this of the alive and healthy humans.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Sianos, Efstathios
  • Σιάνος, Ευστάθιος

Subjects

dc:subject × 24

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/30009

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Sianos, Efstathios; Σιάνος, Ευστάθιος. Σχεδιασμός, κατασκευή και αξιολόγηση μονάδας θερμικής εκρόφησης προσαρμοσμένης σε gc/ms: μετρήσεις εκπνεόμενου αέρα. National Technical University of Athens (NTUA), 2012. http://hdl.handle.net/10442/hedi/30009