Αριθμητική και πειραματική μελέτη φαινομένων ροής ρευστών, θερμότητας και σωματιδίων σε πρότυπους εναλλάκτες θερμότητας
Abstract
dc:descriptionThis dissertation considers the technological problem of gas side particulate fouling that seriously affects the operation of heat exchanger tube bundles in cross-flow. Aiming to optimize the heat exchanger process, including fouling rate reduction with potential heat transfer enhancement and low pressure drop, a passive technique for flow control during the design of the heat exchanger is developed. In particular, although the vast majority of reported studies to date involve cylinders of an identical diameter, here, the implementation of a tube bundle consisting of alternately placed cylinders of different diameter is suggested. Based on observations from an extensive literature survey, initial numerical and experimental studies involve the primal geometry of two unequal sized cylinders in cross-flow, with a diameter ratio of d/D=0.5 placed in tandem and at different longitudinal pitches, SL/D=1.5, 2.0 and 2.5, at the subcritical Reynolds number of ReD=3900. For the numerical study of the flow, temperature and particle field around the cylinder pairs Large Eddy Simulation (LES) was used. The experimental approach included the construction of the cylinder arrangement, where hot wire measurements of the horizontal velocity distribution in the wake were conducted, and flow visualization around them was performed. The preferred primal unequal sized cylinder arrangement was then extended to form a heat exchanger tube bundle, where the effect of the transverse distance between the tubes (ST/D) was also studied, numerically and experimentally. Three tube bundle configurations were designed: the Arrangement AA with d/D=0.5, SL/D=1.5 and SΤ/D=3.6, the Arrangement AB with d/D=0.5, SL/D=1.5 and SΤ/D=2.5, and the Arrangement AG with d/D=1.0, SL/D=2.5 and SΤ/D=3.6. In the numerical study the three arrangements were compared in terms of heat transfer, pressure drop and gas-side fouling rates. Experimentally, the arrangements were constructed and connected to a water circuit/wind tunnel rig where the heat transfer on the external surface of the cylinders and the pressure drop across each configuration were measured. As far as the cylinder pairs are concerned, the study confirmed the initial assumption that velocity fluctuations in the wake of a cylinder are reduced with the upstream installation of another one, half the diameter. Moreover, the two-cylinder configuration with d/D=0.5 and SL/D=1.5 reduced the deposit formation on the second cylinder by 80%, as compared to a pair of equal sized cylinders. With regard to the heat exchanger configuration, when compared to the conventional tube bundle arrangement, the arrangement with d/D=0.5, SL/D=1.5 and SΤ/D=3.6 led to specific (per unit volume) heat transfer enhancement by 30-40% and reduced the particle deposition rates by 30% with indications of a negligible penalty in pressure drop.
Degree
thesis:*- Grantor dc:publisher
- University of Western Macedonia
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Μαυρίδου, Σοφία
- Mavridou, Sofia
Subjects
dc:subject × 22- Εναλλάκτης θερμότητας
- Μετάδοση θερμότητας
- Κύλινδρος
- Επικάθηση
- Σωματίδια
- Πτώση πίεσης
- Αριθμητική μελέτη
- Πειρματική μελέτη
- Ανεμόμετρο θερμού νήματος
- Heat exchangers
- Heat transfer
- Cylinder
- Fouling
- Particles
- Pressure drop
- Numerical study
- Experimental study
- Hot wire anemometer
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Mechanical Engineering