National and Kapodistrian University of Athens
Χαρακτηρισμός της επιφάνειας οστεοενσωματούμενων οδοντικών εμφυτευμάτων
Abstract
dc:descriptionINTRODUCTION: During the last twenty years the number of osseointegrated dental implants used has been steadily increasing worldwide reaching today one million cases per year. The clinical success of dental implants is directly connected to their premature osseointegration. The chemical consistency and surface topography of dental implants is of the utmost importance for both their short and long term success.AIM: The purpose of this research is surface characterization of available on the market and widely used in everyday clinical practice, titanium dental implants. Their surface topography and roughness will be defined as well as their chemical consistency with the use of Scanning Electron Microscopy, Energy Dispersive Spectroscopy and Optic Profilometry.MATERIALS AND METHOD: For the purposes of this research, ten commercially available single titanium dental implants, submitted to a variety of surface treatments, have been selected. The implants are as follows׃ Semados S, Nanotite, PrimaConnex, Lazer-lok, Xive, Axiom, Osseospeed, Seven, Replace and Bicon. Initially, all ten implants will be examined through SEM (Scanning Electron Microscope). Next, the implants will be submitted to surface analysis for elemental definition through EDS (Energy Dispersive Spectroscopy). Finally, the different parameters of the surface roughness of the implants will be studied with the use of the three dimensional optic profilometrymethod.RESULTS AND CONCLUSIONS: Based upon the outcomes of this research the following conclusions are drawn:1.There are similarities among implant surfaces treated with similar methods׃ Xive-Axiom-Seven-Semados S.2.Surfaces with similar topography differed in roughness in a statistically significant degree׃ Osseospeed-PrimaConnex, Semados S-Xive, Bicon-PrimaConnex.3.There were differences in topography and roughness (in a statistically significant degree) among surfaces that were treated with different methods׃ Lazer-lok-Bicon-Xive, Bicon-Seven, Bicon-Xive-Replace, Xive-PrimaConnex, Semados S-Bicon. 4.The elemental composition of the implant surfaces is affected by the treatment methods.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Νικολοβιένη, Δήμητρα
- Nikolovieni, Dimitra
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/30101