Back to search

Aristotle University Of Thessaloniki (AUTH)

Ανάπτυξη νέων αναλυτικών μεθόδων προσδιορισμού θειολών σε τρόφιμα και βιολογικά δείγματα με σύζευξη της υγρής χρωματογραφίας με αυτοματοποιημένα συστήματα ροής

Abstract

dc:description

In summary, the experimental data of the present Dissertation lead to the following:The first study reports the very first application of ethyl propiolate (EP) as anadvantageous pre-column derivatization reagent for the determination of cysteine,glutathione and N-acetylcysteine by liquid chromatography. These thiols werederivatized online under stopped-flow conditions in a sequential injection systemcoupled to liquid chromatography. The reaction was rapidly allowed to proceed understopped-flow conditions in the loop of the LC setup. The formed derivatives wereseparated isocratically using a monolithic stationary phase and were detectedspectrophotometrically at 285 nm. Critical parameters that affected the online precolumnderivatization reaction (e.g. the reaction time and the amount concentration ofEP) and the separation (e.g. pH and the composition of the mobile phase) wereinvestigated. The developed analytical scheme offers a total analysis time of less than10 min. The limits of detection were in the range of 0.24–0.40 × 10-3 mol L-1and thelinearity achieved were up to 200 × 10-3 mol L-1for all analytes. The proposed methodwas satisfactorily applied to the analysis of the selected thiols – that are oftenemployed as antibrowning agents – in fresh fruit samples.The second study reports a new High Performance liquid chromatographic (HPLC)method for the determination of the anti-hypertension drug captopril in human urine.After its separation from the sample matrix in a reversed phase HPLC column,captopril reacts with the thiol-selective reagent ethyl-propiolate (EP) in a postcolumnconfiguration (PCD) and the formed thioacrylate derivative is detectedspectrophotometrically at 285 nm. Automated 4-fold preconcentration of the analyteprior to analysis was achieved by an on - line solid phase extraction (SPE) step usinga Sequential Injection (SI) manifold. The Oasis HLB SPE cartridges offeredquantitative recoveries and effective sample cleaning by applying a simple SPEprotocol. The limits of detection and quantitation were 10 μg L-1and 35 μg L-1respectively. The percent recoveries for the analysis of human urine samples rangedamong 90 – 96 % and 95 – 104 % using aqueous and matrix matched calibrationcurves respectively. The features of the developed method are as follows: i) it is moresensitive and simple compared to the only previously reported PCD method; ii) thesample preparation and analysis steps are fully automated by coupling SI and HPLC; iii) the Oasis HLB SPE cartridges offer quantitative recoveries of the analyte from thebiological matrix, preconcentration potentials and adequate capacity and stability; iv)EP is an excellent reagent for captopril in terms of sensitivity and rapid reaction underflow conditions; (v) the method is capable of determining total captopril since theexcess of the reducing reagent does not interfere in the PCD mode.Finally the last work reports one of the very first applications of on-line post-columnderivatization to hydrophilic interaction chromatography, offering a viable tool for thedetermination of low molecular weight thiolic compounds. More specifically itproposes a new method for the determination of Glutathione and Cysteine in yeastsamples. The analytes were separated isocratically from the sample matrix byHydrophilic Interaction Chromatography (HILIC) and they were detectedspectrophotometrically at 285 nm following on-line post-column derivatization (PCD)by the thiol-selective reagent methyl-propiolate in alkaline medium. The method takesadvantage of the ability of HILIC to retain polar analytes and the well-establishedpotentials of post-column derivatization to the analysis of complicated matriceswithout matrix effects. The main figures of merit included linearity in the range of 5 –200.0 × 10-6 mol L-1and a limit of detection 0.6 × 10-6 mol L-1for both compounds.The absence of matrix effect allowed the determination of cysteine and glutathione invarious yeast samples. Glutathione was present in most of the samples at levelsranging among 0.9 – 3.1 mg g-1, whereas Cysteine was determined in only one sampleat significantly lower concentration. In terms of accuracy, the percent recoveriesranged among 91.2 to 105.6 % for glutathione and 91.6 to 106.9 % for cysteine.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Karakosta, Theano
  • Καρακώστα, Θεανώ

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/30486

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Karakosta, Theano; Καρακώστα, Θεανώ. Ανάπτυξη νέων αναλυτικών μεθόδων προσδιορισμού θειολών σε τρόφιμα και βιολογικά δείγματα με σύζευξη της υγρής χρωματογραφίας με αυτοματοποιημένα συστήματα ροής. Aristotle University Of Thessaloniki (AUTH), 2013. http://hdl.handle.net/10442/hedi/30486