Βελτιστοποίηση μονάδος παραγωγής πόσιμου ύδατος με αφαλάτωση θαλασσινού και χρήση αιολικής και ηλιακής ενέργειας

Abstract

dc:description

In this thesis work, the design, construction, operation and optimization of a small capacity desalination unit for water production using renewable energy sources (sun and/or wind) are attempted. The devices that were designed, constructed and studied were: a) two small centrifugal compressors (12,5cm and 17cm impeller diameters at 14000rpm and 11500 rpm respectively), b) evaporation-condensation falling film devices with vapor compression and c) evaporation-condensation devices with horizontal immerged tubes of polypropylene. The behavior of these devices during operation and their efficiency were examined as well. The desalination method to be applied was then selected, on the basis of the criterion of minimum unit construction cost. The possibility of operation at the expense of wind and/or solar energy was evaluated. The regional wind potential (of Mikra-Thessaloniki) was statistically analyzed, the possibility of the operation of a proper wind turbine (4,5m diameter, 4,5kw nominal power at 13m/s wind speed) was examined and the required solar collector surface area was calculated. Finally, the optimum unit effects number was estimated (4 effects seems to be a reasonable selection). The unit was constructed and its functional characteristics, included those of solar collectors, were studied and evaluated. The performance of the centrifugal compressor was the expected, while the prediction of low efficiency during the operation was completely confirmed (less than 60%). The wind potential of the major area appeared not to differ from the reported in the literature, while the local wind potential was clearly stronger. The operation of the selected solar collectors indicated a rather low efficiency (less than 40%) and this is mainly attributed to their constructive deficiencies. The values of the overall design heat transfer coefficients obtained during operation of the unit, were in agreement with those predicted by the proposed model (in the range of 20 to 30 Βtu/(ft2)(oF)(hr)). The efficiency during the operation (measured as ratio of steam introduced into the first effect to the totally produced condensate) takes on values around 2,2, while its maximum expected value is 3,5 (i.e. 63% of the expected). Further, instability during the operation is inferred. This can be attributed to explosive boiling conditions in the effects, probably due to a hysterisis in releasing the heat transferred to the seawater. The last phenomenon has as a consequence a rather drastic drop of the operating temperature difference between exchanger tubes and shell side. An additional consequence is the reduction of the heat transfer coefficients that finally reduce the unit efficiency.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2004

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Spanomitsios, Stefanos
  • Σπανομήτσιος, Στέφανος

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/30557

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Spanomitsios, Stefanos; Σπανομήτσιος, Στέφανος. Βελτιστοποίηση μονάδος παραγωγής πόσιμου ύδατος με αφαλάτωση θαλασσινού και χρήση αιολικής και ηλιακής ενέργειας. Aristotle University Of Thessaloniki (AUTH), 2004. http://hdl.handle.net/10442/hedi/30557