Back to search

National and Kapodistrian University of Athens

Μελέτη της προσαρμογής του υλικού στα τοιχώματα της κοιλότητας σε εμφράξεις σύνθετης ρητίνης - υαλοϊονομερούς κονίας

Abstract

dc:description

The purpose of this study was to evaluate a) the effect of combined glass ionomer composite resin restoration on gap width in regard to the shape of GI, b) the interaction between acid etching and combined GI/CR restoration on gap along the cavity walls.Cavities were prepared at the buccal and lingual surfaces of extracted human premolar teeth. They were divided in four groups. I-III were restored with GI/CR, GI in different shapes while IV was restored with CR only. Half of the teeth in each group were beveled and etched at the enamel margins. They were stored in water bath at 37o C for 24hrs, then embedded in acrylic resin and sectioned longitudinally through the center of the restoration. They were highly polished with final diamond paste of 0.25μm, observed in optical microscope and pictures were taken at a final magnification on the slide film of 51.2x. The areas pictured were: Α, Ι at the restoration margins, Δ and Ζ at the axial-occlusal and axial-gingival angles, Ε at the middle of the axial wall, Κ at the middle of the GI/CR interface, Β and Θ at the interface of GI/CR and Γ, Η at the occlusal and gingival wall at the GI-tooth interface. According to gap width they were classified as:0: no gap, 1:gap up to 10μm, 2: 10-20 μm, 3:20-30 μm, 4:30-40 μm,5: 40-50 μm, 6:50-60 μm, 7:60 μm and above.The results show that gap width is not the same all along the cavity walls. Areas of outer margins (A,I) showed the smallest gap when enamel had been etched. In non-etched samples groups I,II showed higher gap values than groups III, IV. Two way ANOVA analysis showed interaction of group and etching (A:F=4.180 and p=0.00725, I:F=5.5510 and p=0.0013).In area E the higher values were observed in group IV and were statistically significant different from other groups (F=6.929, p=0.0002) and this was independent of acid etching (F=1.457, p=0.229). The values of area Z were the highest values observed.In conclusion, enamel etching eliminates the gap at the outer margins only, group III had the lower gap values at the margins in non-etched samples, the use of GI even though does not change the marginal gap achieves a better interface especially at the axial wall, whatever was the placement shape of the GI any of them experiences problems at certain areas.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
1995

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Lioumi, Evangelia
  • Λιούμη, Ευαγγελία

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/30735

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Lioumi, Evangelia; Λιούμη, Ευαγγελία. Μελέτη της προσαρμογής του υλικού στα τοιχώματα της κοιλότητας σε εμφράξεις σύνθετης ρητίνης - υαλοϊονομερούς κονίας. National and Kapodistrian University of Athens, 1995. http://hdl.handle.net/10442/hedi/30735