Σχεδιασμός και λειτουργία μονάδων αφαλάτωσης νερού με αντίστροφη ώσμωση: μελέτες περιπτώσεων

Abstract

dc:description

In the present thesis, case studies are presented regarding the design and the operation of two seawater desalination units with reverse osmosis installed at 2007 in Milos island and Corinth Oil Refineries with capacity 2.400 and 1.120 m3/ day correspondingly, as well as one pilot 425 m3/ day Ultrafiltration – Reverse Osmosis unit for the reclamation and reuse of municipal wastewater in the Chersonissos Waste Water Treatment Plant in Crete during 2008. In the framework of this research Milos and Corinth desalination plants have been systematically monitored for 2 years and especially their main operational parameters as the specific energy consumption, the normalized membrane flux, the normalized membrane salt rejection, membrane differential pressure, product water quality and factors contributing negatively in unit reliability. Especially for the membrane performance evaluation the following variables have been recorded systematically: seawater temperature and ionic concentration (through conductivity measurement), membrane high pressure water inlet, membrane high pressure water outlet, product flow, rejection flow, product water salt concentration (through conductivity measurement) and membrane backpressure (if existent). The above mentioned recording were processed in a spreadsheet according to the ASTM D4516 standard in order to evaluate membrane actual performance compared to initial reference (which is considered as the best due to fouling absence). Study of Milos and Corinth cases provided important conclusions: It has been verified that under proper design we can achieve specific energy consumption less than 2.5 KWh/ m3 for small size R/O trains with a capacity of 500 – 2.400 m3/day. Estimating electricity cost in Greece ca 0,08 € / KWh this results to a cost of energy less than 0.2 € / m3.Specific energy consumption as it was expected is strongly influenced by seawater temperature variation and less from the other operational parameters. The choice of positive displacement high pressure pumps and pressure exchanger in the unit design had as a consequence that despite the membrane high pressure inlet increase (for steady production flow and recovery) the specific energy consumption had significantly lower proportional increase. The membrane high pressure inlet increase is confirmed by the membrane normalized flux decline. Especially for the desalination units in Corinth a repeated annual seasonal variation in normalized flux was observed, attributed to the seasonal micro organism growth causing membrane biofouling. According to this the lowest and the highest normalized flux are observed in September and March correspondingly. In all seawater desalination installations studied we had interesting variations in the normalized flux even in systems with common seawater pretreatment. This phenomenon is more intense comparing Milos to Corinth desalination plant which have exactly the same main desalination process design. From membrane normalization flux study we have noticed that in large membrane actual flux reduction, normalization of the recordings does not correctly present membrane fouling. So it is recommended to always compare normalized flux to actual. According to membrane manufacturers recommendations; membrane performance deterioration as normalised flux decline is generally considered 5% annually for the first 3 years of operation. As verified by our research this annual decrease of permeability can be as high as 7- 10% as also reported in bibliography. From the comparison of the normalized membrane salt rejection of Milos and Corinth cases, we have measured significant deviation resulting to permeate conductivity. These deviations are attributed to the special operational parameters of each installation as they are not justified by their design. Recording of the above deviation is important for the evaluation of membrane performance program projections where desalination unit design is based. In the UF-RO unit for wastewater reclamation and reuse case study we have systematically monitored its pilot operation. The most important operational parameters were the reverse osmosis membrane normalized flux due to the increased risk of their uncontrolled fouling and the quality of produced water. As in the other case studies there was a systematic record keeping of the same variables processed in a spreadsheet based on the ASTM D4516 for the calculation of normalized membrane flux, salt rejection and differential pressure. The technologically advanced pretreatment of wastewater effluent with Ultrafiltration membranes allowed desalination unit operation without the need of chemical cleaning for a period of operation exceeding two months, as it was observed by the stability of reverse osmosis membrane normalization flux during pilot operation. It should be also noticed that the reverse osmosis membranes were operating at higher flux per membrane surface unit compared to manufacturers’ guidelines. From the study of the reverse osmosis membrane normalized salt rejection as well as water analyses results it was verified that the water produced had the basic physicochemical characteristics of potable water. Municipal waste water reclamation and recycle UF-RO technology provides significant environmental benefits and as confirmed by the pilot unit installation and operational cost is a very interesting in both technical and financial terms investment proposal for Water and Wastewater Authorities as well as in large hotel complexes and golf courses. Knowledge and experience gained from the present research have been used to design and operate a new reverse osmosis desalination installation at Motor Oil Hellas Refineries, having as overall capacity 6.800 cubic meters per day. Especially for the seawater pretreatment of the above installation a 10.000 m3/ day Ultrafiltration system was designed based on the relevant UF case study. It should be noticed that based in our knowledge so far this is the largest installation of reverse osmosis desalination and the first with Ultrafiltration pretreatment in Greece.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Υφαντής, Νικόλαος

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/31585

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Υφαντής, Νικόλαος. Σχεδιασμός και λειτουργία μονάδων αφαλάτωσης νερού με αντίστροφη ώσμωση: μελέτες περιπτώσεων. National Technical University of Athens (NTUA), 2011. http://hdl.handle.net/10442/hedi/31585