National Technical University of Athens (NTUA)
Heat transfer computational methods which can also be applied to geothermal field of study for energy saving and environmental benefits
Abstract
dc:descriptionThe current work is focused on the Ground Source Heat Pump Systems (GSHPSs) coupled to closed vertical ground loop. Several factors that affect the system’s performance are examined. Two different approaches are developed. In the first one, an overall view of system’s performance is studied using GLD 2009, GLHEPRO 4.0a and TRNSYS 17. The system is examined as a total of unbreakably connected parts. A parametric analysis is performed to examine the influence of undisturbed ground temperature, Ground Heat Exchanger (GHE) length and borehole separation distance to system’s operational characteristics, so as to cover given building loads. In the second one, the operation of parts is examined independently of the system. The borehole thermal resistance is examined through different types of analysis such as analytical correlations, commercial software GLD 2009 and 2-D finite element analysis through COMSOL 4.0a. Despite the different type of analysis, the deviations are small and that is why borehole thermal resistance output values are considered satisfactory. In addition, MATLAB codes are built to simulate the operation of heat pump and open circuit cooling tower that may be included in a Hybrid Ground Source Heat Pump System (HGSHPS). By studying heat pump’s refrigeration cycle, alternative refrigerant mixtures to R-410A are proposed. Furthermore, the performance of cooling tower is evaluated with the ratio pressure drop per packing height for four packings. The results are generally applicable to the estimation of the performance of these devices and not restricted only to geothermal applications. Moreover, a HGSHPS coupled to a closed circuit cooling tower is studied. A new strategy is developed to control this system so as to minimize its electric power consumption. Despite the fact that it is designed considering only the net cooling period, it is a well-promising policy because it is based on the continuous monitoring of system’s previous hourly state, so as to adjust its operation to the following hour (feedback).
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Sagia, Zoi
- Σαγιά, Ζωή
Subjects
dc:subject × 20- Γεωεναλλάκτης
- Γεώτρηση
- Αντλία θερμότητας
- Ψυκτικός πύργος
- Σύστημα αβαθούς γεωθερμίας
- Υβριδικό σύστημα
- Στρατηγική ελέγχου
- Γεωθερμική ενέργεια
- Ground heat exchanger
- Boreholes
- Heat pump
- Cooling towers
- Ground source heat pump systems
- Hybrid ground source heat pump system
- Control strategy
- Geothermal energy
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Mechanical Engineering
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/31687