National and Kapodistrian University of Athens
Ασφάλεια και αποτελεσματικότητα με μονοπολική, διπολική και υπερηχητική διαθερμία: πειραματική μελέτη
Abstract
dc:descriptionPurpose. Hemostasis is a fundamental principle of surgery. The quest for safer and moreefficient hemostatic techniques, both in open and laparoscopic surgery, has provided uswith several new coagulating tools. We compared the safety and efficacy of monopolarelectrocoagulation (ME), bipolar electrocoagulation (BE), Ligasure (LS), a modern bipolarvessel sealing system, and Ultracision (UC), a system of ultrasound energy based shears.We also studied the healing process after their use. The safety and efficacy of the Ligasure-8 Generator with the new Ligasure V 5-mm forceps (Valleylab, Tyco Healthcare) (LS) andthe Ultracision Harmonic Scalpel Generator 300 with the new 5mm 36p Harmonic Aceforceps (Ethicon Endo-Surgery ING) (UC) are compared.Methods. We used ME, BE, LS and UC, to coagulate and divide the short gastricvessels of sixteen white male New Zealand rabbits were randomly allocated into 4groups, and for the new LS and UC twenty New Zealand rabbits were randomlyallocated into 2 groups . The animals for the first four groups were killed after 3, 7,14, or 21 days, and for the last two groups after 28 days and the coagulation sites andthe adjacent gastric wall were examined histologically. The speed of each method, thenumber of the times it had to be applied, gastric perforation rates and histopathologicfindings were recorded.Results. For the four study groups, LS and UC achieved complete hemostasis without anycomplications. Conversely, ME and BE often resulted in failed coagulation and perforationof the neighboring gastric wall from a side thermal injury. Histologically, LS demonstratedthe mildest side thermal injury and the fastest healing process. We noted greater thermalinjury and inflammatory response after UC than after LS on days 7 and 14; however, MEand BE caused the most severe lesions. For the two study groups with the new LS and UC,approximately the same number of applications was necessary. A tendency for deeper andmore severe histopathologic damages was seen with UC. UC was significantly faster butresulted in contained perforation in 3 cases against 1 for LS (difference statistically notsignificant).Conclusions. LS and UC are clearly the safest and most efficient methods ofcoagulation, whereas ME and BE could cause serious clinical and histologicalcomplications. A tendency for deeper and more severe histopathologic damages was seen with UC. For routine fast dissection, UC is satisfactory, but where prevention ofthermal injury is important, LS may be more appropriate.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Gialikaris, Spyridon
- Γιαλικάρης, Σπυρίδων
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/33101