Back to search

Aristotle University Of Thessaloniki (AUTH)

Ενδαγγειακή αποκατάσταση ανευρύσματος κοιλιακής αορτής: μηχανικές ιδιότητες που συμβάλλουν στη στήριξη του ενδομοσχεύματος

Abstract

dc:description

Objective: To evaluate the differences of proximal, distal and overall fixation mechanisms within 8 commercially available endografts and compare their fixation ability to each other. Moreover various parameters were validated concerning their influence upon fixation. Methods: 20 human cadaveric aortas were surgically dissected from renals to iliac bifurcations, left in situ and transected 2 cm below the renals and above aortic bifurcation, to mimic AAAs’ proximal and distal landing zones. The mean proximal infrarenal aortic diameter was 20,5 mm (range 19,2-21,9). 8 stent grafts were implanted (Anaconda, Excluder, Talent, AUI Endofit, Zenith, Endurant, Powerlink Endologix and VI Extender Cuff) from the femoral arteries, according to manufacturers’ guidelines. In addition a PTFE graft was anastomosed to the aorta or iliac artery with running PTFE suture. Distal force was applied to the flow divider of each graft, either fully or only proximally deployed, via a sensitive force gauge. Minimum displacement force (DF) needed to dislodge the stent graft from the infrarenal neck was recorded. Measurements were repeated after molding balloon dilatation at the proximal neck. Iliac legs were measured as well, for chephalad displacement, either after minimum or maximum iliac fixation and before and after balloon dilatation. Results: Within the self expanding endografts, Zenith recorded the highest proximal DF 34.50 N (31.35-37.50), Anaconda showed the 2nd highest proximal DF 28.75 Ν (26.50 -31.05), Endurant recorded the 3rd highest DF 26.75 Ν (24.60-28.70), Excluder was measured 17.90 Ν (17.30-18.85), Talent recorded DF 14.90 Ν (14.40-15.30), Powerlink needed a DF of 13.65 Ν (12.50-14.90), Endofit recorded DF was 12.15 Ν (11.00-13.40). ΒΕ VI Extender cuff, proximally deployed, needed DF was 27.70 Ν. PTFE anastomosis recorded the highest proximal DF 76.20 Ν (66.40-79.00). Molding balloon dilatation produced a significant DF increase in “hooked” grafts but an insignificant in “hookless”. Increased length of iliac landing zone increases distal fixation ability. Hooks and barbs significantly enhance proximal and total fixation. Suprarenal stent does not significantly affect fixation. When columnar strength was incorporated, full deployment (body and limbs) caused significant increase in DF compared to proximal deployment only. When columnar support was unavailable, full deployment caused marginal increase in DF compared to proximal deployment only. Balloon expandable VI Extender cuff recorded significant DF that was higher than the mean DF of self expanding endografts. Conclusions: Hooks and barbs and balloon dilatation significantly enhance proximal and total fixation. Suprarenal stent does not significantly affect fixation. Length of iliac landing zone increases fixation ability.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Melas, Nikolaos
  • Μελάς, Νικόλαος

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/33157

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Melas, Nikolaos; Μελάς, Νικόλαος. Ενδαγγειακή αποκατάσταση ανευρύσματος κοιλιακής αορτής: μηχανικές ιδιότητες που συμβάλλουν στη στήριξη του ενδομοσχεύματος. Aristotle University Of Thessaloniki (AUTH), 2010. http://hdl.handle.net/10442/hedi/33157