Ανάπτυξη νέων ποτενσιομετρικών αισθητήρων φωσφορικών ιόντων
Abstract
dc:descriptionThe development of novel phosphate potentiometric sensors based on the chemical recognition of phosphate using bidentate organotin compounds is presented.Various organotin compounds were tested as phosphate carriers in polymer based Ion- Selective Electrodes (ISEs). Remarkable selectivity of bidentate organotin compounds towards phosphate was observed, which depends on the structure of the organotin compound. During the process of the phosphate carrier evaluation the best selectivity towards phosphate was obtained by the carrier bis-(dich1oropheny1stanny1)-methane. Unfortunately, the ISEs based on this carrier showed poor reproducibility and short lifetime due to hydrolysis of the organotin carrier upon contact with water. In order to overcome these problems the influence of different membrane components in the ISE operation was studied. Such components were the plasticizer, the ionic additives and the polymer. It was found thai the use of plasticizer TEHP instead of DOS improves considerably the electrode lifetime. It was also observed that the use of plasticizer FP-NPE in combination with the polymer PVC-COOH gives phosphate ISEs with good functional characteristics, such as linear calibration curve to phosphate with a detection limit of lpM. Although after the membrane optimization process remarkable improvements on the development of phosphate ISEs were achieved, the short electrode lifetime (few hours of continuous use) remained the greatest problem. For this reason a novel type of Solid-Contact ISEs (SC-ISEs) was developed. In this approach the ISE internal filling solution was a 5% (w/w) solution of the carrier bis-(dichloropheny1stannyl)-methane in plasticizer instead of the aqueous internal filling solution used in conventional ISEs. Two types of SC-ISEs were constructed: The SC-ISEs with conductive Carbon rod (CSC-ISEs) and the SC-ISEs with Liquid Membrane (LMSC-ISEs). The LMSC-ISEs constructed with the plasticizer FP-NPE had lifetime of fifteen days under continuous use. The electrode selectivity towards phosphate was very good (log •.,• .. : SCO, -1.6; C1O4 ”, -2.0; Cl, -2.7; SOA 2, -2.2; measured by SSM). Linear calibration curves to phosphate in buffered solutions of pH=5.0 with a slope of 56mV/decade and a detection limit of 3.2-10a were obtained. The electrodes can be used in a pH range of 3-8. The electrode responded to phosphate concentration changes within lmin. Stable potential values were obtained with a reproducibility of 3.7mV/concentration measurement. The LMSC-ISEs were also used in FIA measurements with great success. In the FIA mode the electrodes showed very good baseline return, while the reproducibility of peak height was of 2.4mV/concentration measurement.Based on these findings the phosphate sensors constructed will soon find applications in environmental and clinical analysis after minor optimizations.
Degree
thesis:*- Grantor dc:publisher
- University of Crete (UOC)
- Year dc:date
- 1999
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsagkatakis, Ioannis
- Τσαγκατάκης, Ιωάννης
Subjects
dc:subject × 27- Φωσφορικά
- Ποτενσιομετρικοί αισθητήρες
- ISEs
- SC-ISEs
- ΜΕΜΒΡΑΝΗ
- Ιονομεταφορείς
- Φθοριούχα
- Χλωριούχα
- Οργανοκασσιτερικοί
- Επιλεκτικότητα
- Χημική αναγνώριση
- Ανιόν
- Phospate
- Organotin carriers
- Selectivity
- Chemical regognition
- Membrane
- Potentiometric sensors
- Fluoride
- Chloride
- Anion
- Φυσικές Επιστήμες
- Χημεία
- Γεωεπιστήμες και Επιστήμες Περιβάλλοντος
- Natural Sciences
- Chemical Sciences
- Earth and Related Environmental Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/33553