Συγκριτική μελέτη διαθλαστικών επεμβάσεων Lasik με femtosecond laser και μηχανικό μικροκερατόμο
Abstract
dc:descriptionABSTRACT PURPOSE The purpose of this prospective study is the comparison of Lasik with mechanical microkeratome vs Lasik with FS Laser. MATERIAL AND METHOD. 200 eyes underwent to Lasik with mechanical microkeratome for correcting myopia or hyperopia and astigmatism. Respectively 200 eyes had lasik with femtosecond laser for correcting myopia or hyperopia and astigmatism. The following parameters were included in the study and were measured before Lasik and post lasik at months 1 and 3 : Corneal thickness and endothelial cell number, (both were measured with specular microscope) and intraocular pressure checked with Goldmann and Pascal tonometer. True flap thickness was also measured with the aid of intraoperative pachymetry after flap lifting and prior to excimer laser application and compared with the intented flap thickness. An other parameter that was recorded was the final refractive result, the final uncorrected visual acuity and finally any change regarding spherical aberration, with the aid of wavefront aberrometer. Results 1) MYOPIA 178 eyes of 89 patients underwent to LASIK with mechanical microkeratome (LΜΚ) for the correction of myopia and astigmatism. Respectively in femtolasik (LFS) underwent 166 eyes of 83 patients. 344 eyes were included in the study in total. On all the above aferomentioned parameters there was no statistically significant difference noted between the two methods ( p>0,05), although LFS had a slight superiority, with less effect on all of these parameters. Especially regarding flap thickness, LFS produced flaps with a true thickness more proximal to the initial intented thickness and also with less deviation. The only parameter where there was a statistically significant difference noted was regarding spherical aberration where it was found that LMK induced more aberrations whereas LFS brought a small reduction ( p < 0,05). 2) HYPEROPIA On hyperopic LMK underwent 22 eyes of 11 patients. On hyperopic LFS underwent 36 eyes of 18 patients. There were 58 eyes involved in the study in total. On all the above mentioned parameters, although LFS had a slight superiority, with less effect on all the parameters there was no statistically significant difference noted between the two methods ( p > 0,05). The only parameter where there was a statistically significant difference noted was regarding spherical aberration where it was found that LMK induced more aberrations whereas LFS brought a small reduction ( p < 0,05). Conclusions: With the only exception of spherical aberration where LFS is significantly better and there was noted a statistically significant difference, there were no other significant differences noted, despite the minimal LFS superiority . One can safely declare that similar alterations have occurred in both methods and also that these alterations happen within a small and predictable range of values. Therefore a very good safety profile is shown on both methods.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Dranidis, Georgios
- Δρανίδης, Γεώργιος
Subjects
dc:subject × 13Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/35018