Διερεύνηση της λειτουργικής συμπεριφοράς συστήματος μετατροπής αιολικής ενέργειας σε ηλεκτρική αποτελούμενο από ασύγχρονη μηχανή διπλής τροφοδοσίας και ηλεκτρονικούς μετατροπείς ισχύος σε δυναμικές καταστάσεις

Abstract

dc:description

In last decades, the so-called “renewable or green energies” have gained the worldwide community interest, because of the increasing demand of electric power and the urgent need to reduce the dependence on fossil fuels. During last years, wind energy has grown over standing today as the leader of the RES. Initially, the Fixed Speed Wind Energy Conversion Systems (FS-WECS) have been designed. However, due to the need of maximum power production in a wider wind speed range, Variable Speed Wind Energy Conversion Systems (VS-WECS) have been developed and prevailed in recent years. The VS-WECS are divided into two types (technologies). The first one is the variable speed concept with the Doubly-Fed Induction Generator (DFIG-WECS) and the other type is equipped with a full-scale power electronic converter. Between these two technologies the DFIG-WECS has become the most popular due to the fact that it can be operated under a wide range of wind speed. In addition, establishing the power electronic converter in the rotor circuit, through which only the 30% of the total power is transferred, results in better and lower power converter dimensioning. So, DFIG-WECS becomes an economical choice. However, problems arise in the operational behavior of these systems when they operate under dynamic conditionsThis thesis deals with this problem and specifically with the investigation of the operational behavior of the DFIG-WECS under strong dynamic conditions. According to the international literature, the most common dynamic conditions for DFIG-WECS occur when faults occur (endogenous factors). Typical faults that have been investigated mostly due to their severity for the smooth operation of these WECS are: symmetrical and asymmetrical grid faults, like voltage sags, symmetrical and asymmetrical short-circuits etc. Other typical types of faults in wind energy conversion systems are the faults in induction machine. Also, a kind of fault, which is very likely to happen, is the open- or short- circuit in the switches of the back-to-back power electronic converter. Another important dynamic condition s affecting DFIG’s operational behavior is wind speed variations especially wind gusts (exogenous factor). The results of this research are important because they can be used by a global control system of DFIG-WECS for controlling smoothly their operational behavior.The method adopted for carrying out the above investigation is simulation in Matlab/ Simulink. This was due to the fact that there are difficulties implementing so large scale systems in the laboratory and also these dynamic conditions.In our work we followed the following steps. Firstly, thewholeDFIG-WECShasbeenconsideredindetailanditsoperationprincipleshavebeenanalyzedinsteadystate. This detail has been used as a basis for the DFIG dynamic model development. Subsequently, each part of the DFIG dynamic model has been analyzed using dynamic equations and a model of a 2 MW system in Matlab/ Simulink has been developed, firstly implemented with open loop control system and secondly with a closed loop control system. Secondly, a constant wind speed, the operational behavior of the DFIG has been studied under subsynchronous mode both in healthy and in faulty condition. More specifically, the faults, that have been considered, are open-circuit faults in the IGBTs of the back-to-back power electronic converter, grid short-circuits (1φ, 2φ, 3φ)and voltage sags (symmetrical and asymmetrical). As far as open-circuit faults are concerned, the waveforms and the harmonic spectrum of basic system variables could be the basis of a diagnosis method development. In addition, the DFIG synchronization process has been studied implementing a grid voltage zero-crossing method.Thirdly, the whole DFIG model, consisting of the wind turbine, pitch control system, MPPT system, asynchronous machine, back-to-back power electronic converter and its closed loop control system implementing vector control, a transformer and grid, has been developed and simulated under strong dynamic conditions, that have been referred before. More specifically, the DFIG reaction under different wind gust profiles (with ramp and step function profile) and also under converter faults (open- and short-circuit) has been investigated. Moreover, a sensitivity analysis of the pitch control system has been carried out. In addition, in this thesis an investigation on how does the choice of the DFIG parameter values affect on the whole system behavior has been done via simulation. A second model of a 5 MW DFIG has also simulated under a wind gust and converter faulty condition in Matlab/ Simulink to compare its behavior with the corresponding one of the 2 MW system. Also, an “anti-windup” system has been implemented and added in all of the PI controllers to improve system behavior under a wind gust (both with step function and with ramp profile).Interpreting the results of the simulations, it has been concluded that the most severe dynamic condition is the wind gust and especially the one with step function profile. The second one is the short-circuits in IGBTs, but it is less possible to happen than the open-circuit faults that cause great torque oscillations and overcurrents in DFIG rotor and this could lead to system breakdown. The third one is the short-circuit in rotor terminals. More specifically, a 2φ short-circuit causes torque oscillations (possible mechanical part damage), while a 3φ short-circuit causes very high peak rotor current values (possible electrical part damage). If grid voltage is harmonically distorted, oscillations in basic system variables (e.g. rotor speed, torque, machine currents) appear and this also has been observed when an oscillation in wind speed has been considered. Moreover, great torque and machine currents oscillations appear in case that an open-circuit fault occurs in DC link.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Giaourakis, Dimitrios
  • Γκιαουράκης, Δημήτριος

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/35334

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Giaourakis, Dimitrios; Γκιαουράκης, Δημήτριος. Διερεύνηση της λειτουργικής συμπεριφοράς συστήματος μετατροπής αιολικής ενέργειας σε ηλεκτρική αποτελούμενο από ασύγχρονη μηχανή διπλής τροφοδοσίας και ηλεκτρονικούς μετατροπείς ισχύος σε δυναμικές καταστάσεις. University of Patras, 2015. http://hdl.handle.net/10442/hedi/35334