Technical University of Crete (TUC)
Εξοικονόμηση ενέργειας στο δομημένο περιβάλλον με έμφαση στο φυσικό φωτισμό
Abstract
dc:descriptionThe issue of energy balance in buildings has a significant importance nowadays, since conventional energy sources are running out and become extremely expensive. Fundamental environmental design parameters should be carefully implemented in the overall design decisions. A building’s skin is the design element that has to balance all environmental dynamics between interior and exterior. Radiation control in transparent façade elements is a very delicate subject due to the fact these elements are the ones that are the most vulnerable to it. Sun control “machines” play a major role in the control of incident solar and thermal radiation for transparent elements. Additionally, they determine the final aesthetics of the façade and constitute an expression of the architectural language of the designer. The research’s starting point is the fact that the conception of shading systems as sun control “machines” introduced in the ‘60s, has changed. The integration of PV elements in their surfaces is the key factor that calls for a reexamination of their performance within the actual environmental standards. The fundamental geometric rules for effective Shading Design derive from the necessity of preventing direct solar radiation from entering the interior. The main objective of this research is to resolve an energy balance contradiction that originates from fixed shading devices: the simultaneous reduction of a building’s cooling loads and the increase of its electric light needs. In order to balance the positive fact of the decrease of cooling loads that fixed SD pose and the negative fact of the increase of electricity needs for lighting and thermal comfort, the electricity produced through integrated PV systems has been examined as a potential energy balance solution for various SDs geometries. We compared all SDs with integrated PV energy and comfort performance with shading systems of simple glazing. The research focuses to a typical office building unit. We have used the office originally defined in the European Commission Joule project REVIS (VanDijk, 2001) and further refined in the International Energy Agency Solar Heating and Cooling (IEA SHC) programme Task 27 (Performance of solar facade components) (VanDijk, 2002). The same specifications are used in the EC project SWIFT (http://www.ist‐swift.org/), for IEA SHC Task 25 (Solar assisted air conditioning of buildings, http://task25.ieashc. org/) and Task 31 (Daylighting Buildings in the 21st century, http://task31.ieashc. org/) (Nielsen et al., 2003). The choice of examining the function of office buildings is due to the fact that office units have very specific requirements of daylight levels according to the task of the users and according to the position of the subjects in relation to the opening. The electricity needs are calculated for the worst case scenario of the minimum requirement of 500lux at the desk level and it is measured as Average Daylight Autonomy for the whole year. Daylight Autonomy is represented as a percentage of annual daytime hours that a given point in a space is above a specified illumination level. It was originally proposed by the Association Suisse des Electriciens in 1989 and was improved by Christoph Reinhart between 2001 ‐ 2004. It considers geographic location specific weather information on an annual basis and it is related to electric lighting energy savings if the user defined threshold is set based upon electric lighting criteria. The user is free to set the threshold above which Daylight Autonomy is calculated (Tzembelikos & Athenitis, 2007). For the office units examined in this research the threshold is set to 500 lux on the desk level, as mentioned before. […]
Degree
thesis:*- Grantor dc:publisher
- Technical University of Crete (TUC)
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mandalaki, Maria
- Μανδαλάκη, Μαρία
Subjects
dc:subject × 12Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/35434