Back to search

University of Thessaly (UTH)

Επιδημιολογική μελέτη λεγεωνέλλωσης σε συστήματα υψηλού κινδύνου

Abstract

dc:description

BackgroundLegionnaires' disease continues to be a public health concern in most of the countries and especially in touristic places. This study was scheduled in order to investigate Legionella spp. colonization of high risk water systems. For this purpose water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships were investigated in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Moreover cooling towers of public buildings were also included since they can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Legionnaires' disease outbreaks were linked with cooling towers in previous studies. The main objective of this study was to identify risk factors for contamination of the water systems and asses effectiveness of control measures.MethodsWater systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Τhe characteristics of the ships and WDS were recorded by using a detailed questionnaire. Moreover, a total of 96 cooling towers of public buildings were registered and inspected by using standardized questionnaires. In total, 539 water samples were collected by all water systems by using a water sampling form and were microbiologically tested. All the results were linked for analysis purposes by using a unique identifier. In order to identify risk factors for legionella contamination, bivariate analysis and logistic regression analysis were conducted. ResultsThe 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from ferries WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp.Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (≥ 500 cfu L−1), and 30 (23%) were heavily contaminated (≥ 104 cfu L−1). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila.Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was < 0.5 mg/L (RR = 2.23; P = .01), and with total plate count (P = .001). Colonization was negatively associated with chemical disinfection (RR = 0.2; P = .0003) and with the presence of a risk assessment and management plan (RR = 0.12; P = .0005). A statistically significant higher age (P = .01) was found in legionellae-positive cooling towers (median, 17 years; interquartile range [IQR] = 5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR = 1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration ≥ 1000 cfu L−1. ConclusionWDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members.. Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and management plan. Water chlorination effectively reduces legionellae contamination. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. Proper training of cooling tower operators and crew members is paramount.

Degree

thesis:*
Grantor dc:publisher
University of Thessaly (UTH)
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Goutziana, Georgia
  • Γκουτζιάνα, Γεωργία

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/35486

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Goutziana, Georgia; Γκουτζιάνα, Γεωργία. Επιδημιολογική μελέτη λεγεωνέλλωσης σε συστήματα υψηλού κινδύνου. University of Thessaly (UTH), 2014. http://hdl.handle.net/10442/hedi/35486