Μελέτη των πολικών και μη πολικών οργανικών ενώσεων στη λεκάνη απορροής του ποταμού Στρυμόνα με συνδυασμό ενεργής και παθητικής δειγματοληψίας

Abstract

dc:description

Organic micropollutants entering the aquatic environment may pose severe threat on aquatic ecosystem and human health. The occurrence of organic micropollutants in Strymonas and possible impacts from pollution sources were studied. Water Framework Directive (WFD) introduces a list of 33 priority substances with defined environmental quality standards (EQS) (EC 2000; EC 2008). In addition to these priority pollutants, there is also concern for various hazardous chemical compounds that may be released into aquatic environment (EC 2006) and consequently the identification of specific pollutants at the river basin. Therefore, it is imperative to have analytical methods with adequate selectivity for the unambiguous detection and confirmation of these substances. A multi residue method based on gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the determination of 70 organic compounds from a wide range of chemical groups/families (organochlorinated pesticides, organophosphorous, carbamates, compounds of triazine and urea, PAHs, PCBs, pharmaceuticals, phenols and triazole) in surface waters. The procedure involved clean up with solid phase extraction (SPE) on OASIS HLB cartridges. The method was validated according to the Commission Decision 2002/657/EC, at the validation level of 500 ng/ml. The accuracy and precision of the method were satisfactory. The recoveries ranged from 50% to 110% with the CVs (%) ranging from 0.84% to 27.4%. The LODs varied from 6.0 ng/L to 40 ng/L and the LOQs from 20.1 ng/L to 134 ng/L. The expanded uncertainties as a relative value (U) ranged from 5.98% to 37%. The method proved to be sensitive and reliable and hence it is useful for surface water control programs. Most conventional environmental screening methods for pollutants in water involve grab sampling. Moreover, three types of passive samplers (SPMDs, POCIS-Pharm, POCIS-Pest) were employed along Strymonas River for the assessment of polar and non-polar organic micropollutants along the river. Organochlorinated (OCPs) and polychlorinated biphenyls (PCBs) were also analysed in fish tissues. The procedure involved clean up with gel permeation chromatography (GPC). Recovery test were employed in passive samplers and fish tissues and recoveries ranged from 60-110% for passive samplers and 80.4-130% for fish tissues in accordance to the proposed range for these classes of contaminants. Three sampling campaigns were conducted with active and passive sampling in the year 2013 in order to cover changes in hydrological conditions (high-low flow) as well as possible impacts from seasonally dependent inputs (i.e. agriculture runoff). Passive sampling has gained growing attention as a sampling approach that overcomes limitations of active sampling. It is based on the free flow of pollutants from the sampled medium to a receiving phase of the sampling device. Results from passive sampling were in relative line with biological passive monitoring by fish. Moreover, bioavailable TWA water concentrations were significantly associated with apparently dissolved water concentrations of active sampling. Pesticides are the most ubiquitous pollutants. Spatial and temporal variations were observed suggesting different inputs from pollution sources along the river as well as influence of hydrological conditions. Risk Assessment was estimated with EU Technical Guidance Document (2003) which is an implementation of both WFD and REACH (EC Regulation 2006).

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Terzopoulou, Evangelia
  • Τερζοπούλου, Ευαγγελία

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • BY_NC_ND
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/35487

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Terzopoulou, Evangelia; Τερζοπούλου, Ευαγγελία. Μελέτη των πολικών και μη πολικών οργανικών ενώσεων στη λεκάνη απορροής του ποταμού Στρυμόνα με συνδυασμό ενεργής και παθητικής δειγματοληψίας. Aristotle University Of Thessaloniki (AUTH), 2015. http://hdl.handle.net/10442/hedi/35487