Back to search

University of Patras

Υπολογιστική και πειραματική διερεύνηση ροϊκής συμπεριφοράς τριχοειδών αντλιών και εφαρμογή σε συστήματα θέρμανσης με ηλιακή ενέργεια

Abstract

dc:description

Present research was conducted in Fluid Mechanics Laboratory of the Mechanical Engineering and Aeronautics Department, University of Patras, and was financed by the operational programme «Herakleitos II», Education and Lifelong Learning Investing in knowledge society.Modern demands in controlling heating load of the cooling systems of mechanical or electrical components are increasing. Cooling systems are divided in active and passive systems. In active systems energy is transported due to sensual heat. While in passive systems due to working fluid latent heat of evaporation because of capillary forces developed in the porous wick inside the evaporator. Passive systems are preferred compared to active systems because they can transfer larger amount of heat, are more reliable, since there are no moving parts, and, finally, lifetime period is longer.The Capillary Pumped Loop (CPL) is a device proper for thermal management control, and was investigated in the present PhD study. The CPL operating principle is based on capillary action, developed in the liquid-vapor phase interface of the working liquid in the porous wick inside the evaporator, and working fluid evaporation and condensation latent heat. The result is that the working fluid is displaced inside the loop without any mechanical pump and heat load is transported in large distances. CPL main components are an evaporator, a condenser, a liquid line, a vapor line and a reservoir.Research regarding the CPL experimental models so far concentrated in the evaporator start-up and steady working state conditions. For all those cases heat load was applied through electric resistances. In the present study heat load was alternatively applied through solar radiation using a solar simulator, designed for this purpose. In order to achieve higher temperature in the evaporator external wall and increase solar radiation exploited, a parabolic mirror was used in combination with a solar collector. The experimental installation was designed in such a way to study the behavior of a CPL when heat load was imposed under different loop charging pressures and for several evaporator inclination angles. Experimental results where compared to the results acquired for evaporator operating at zero inclination angle. The initial values of the working fluid temperature were 15, 25, 35 and 45 oC, of the charging pressure 0,05, 0,15, 0,25 bar and of the inclination angle 8, 16 and 23o. The duration of the experiments was initially ten hours, in order to simulate CPL operating during a typical summer day, and then increased to twenty four hours to investigate continuous operation during all day. In the second section of this study two and three dimensions, 2D and 3D, computational models are presented designed in Gambit, Fluent Inc., based on the exact dimensions of the experimental ones.Computational results were derived for water, acetone and ammonia, as working fluid, for zero inclination and the three values of angles mentioned above. Models were customized for different porous wick heated length and working liquid of different saturation temperature.Comparative figures for all working fluids are presented whether evaporator was under inclination angle or not. Moreover, those comparative figures reviled that water was more suitable as working fluid under steady operating state. In the third section the numerical model simulating the overall CPL function is presented and comparative figures between experimental, computational and numerical results are given, for the same operating conditions.In the last section a potential solar CPL heating/cooling system for domestic use is presented. This potential system could meet the demands for using renewable energy sources in order to reduce electrical energy consumption, save money and protect the environment at the same time.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Avgerinos, Nikolaos
  • Αυγερινός, Νικόλαος

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/35529

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Avgerinos, Nikolaos; Αυγερινός, Νικόλαος. Υπολογιστική και πειραματική διερεύνηση ροϊκής συμπεριφοράς τριχοειδών αντλιών και εφαρμογή σε συστήματα θέρμανσης με ηλιακή ενέργεια. University of Patras, 2014. http://hdl.handle.net/10442/hedi/35529