dc:descriptionBackground: The response of the left ventricle (LV) to cardiac resynchronization therapy (CRT) device implantation has only been studied in the short-term (usually in the 3-to-6 month time frame), whereas data on long-term (12 months or longer) LV response are limited. Moreover, data on the response of LV myocardial deformation parameters, which have been recently demonstrated to bear superior prognostic value over conventional LV functional indices in patients with heart failure (HF), are scarce in post-CRT patients. Of note, no data exist for these parameters beyond the 6-month timeframe . Objectives: Our primary aim was to systematically record, using both conventional and novel echocardiographic indices (myocardial deformation), the long-term (12 months or longer) response of the left ventricle after CRT-D device implantation in patients with advanced heart failure receiving optimal medical therapy. Our secondary aims were to (a) record the long-term response of left ventricular dyssynchrony assessed with myocardial deformation indices in these patients; (b) correlate left ventricular dyssynchrony indices before CRT-D device implantation with long-term response of the left ventricle, and (c) correlate both conventional and novel left ventricular function indices before implantation with long-term response of the left ventricle after CRT-D device implantation.Methods: We evaluated the long-term response to CRT using standard and strain echocardiography in 57 patients (52±15 years; 40 male; 12 female; 15 with HF of ischemic etiology) who received a CRT device with defibrillator capacity (CRT-D) between 1/2004 and 12/2005. For this purpose, we used both conventional measurements and myocardial deformation imaging to analyze pre-implant echocardiograms and all follow-up echocardiograms beyond 12 months in the same patients. Results: Median ejection fraction (EF) at baseline was 22% (17% to 25%); global longitudinal, radial, and circumferential strain were -6.5% (-5.0% to -8.4%), 10.4% (6.9% to 15.1%), and -7.6% (-5.5% to -10.8%), respectively. After a median of 42 months, EF increased by 5% (-1% to 15%; p<0.001), with improvements in circumferential (-3.2% [-5.2% to 1.5%]; p=0.001), longitudinal (-0.5% [-3.4% to 1.2%]; p=0.035), and radial (1.4% [-1.1% to 9.2%]; p=0.035) strain; changes in volumes were non-significant. EF improvement ≥5% was observed in 29 patients (50.9%). Relative improvement ≥15% in longitudinal, radial, and circumferential strain was observed in 26 (45.6%), 29 (50.9%), and 37 (64.9%) patients, respectively. Improvement in longitudinal strain and EF was strongly associated with lower rates of HF-related and all-cause readmissions. We observed a wide range of long-term LV responses to CRT, with approximately 50% of patients showing favorable responses.Conclusions: We observed a wide range of long-term LV responses to CRT, with approximately 50% of patients showing favorable responses.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kalogeropoulos, Andreas
- Καλογερόπουλος, Ανδρέας
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/35530