Aristotle University Of Thessaloniki (AUTH)
Προσδιορισμός των υδροδυναμικών συνθηκών λειτουργίας των ορθοτόπων νεοκύστεων με κλασική και συνεχή φορητή υδροδυναμική μελέτη
Abstract
dc:descriptionUrodynamic evaluation of neobladders in patients subjected to radical cystectomy and orthotopic diversion is mandatory during their postoperative period. The aim of the current study was to determine the diagnostic accuracy of conventional and ambulatory urodynamics in estimating neobladder function. We evaluated 32 patients who underwent radical cystectomy and orthotopic Hautmann W neobladder with Abol Enein- Ghoneim uretero-intestinal anastomosis, due to bladder cancer. Initially, the patients were examined using both conventional and ambulatory urodynamics (UDS). Before that, they completed ICIQ, SF-36, FACT-G-VCI and BECK BDI questionnaires regarding incontinence, general quality of life, bladder cancer specific quality of life and depression. Data processing was based on guidelines provided by International Continence Society and statistical analysis was performed with SPSS software, version 20.0. Conventional urodynamics detected a very high mean intravesical pressure at maximum capacity (53.7 ±17.5 cmH2O). Ambulatory urodynamics calculated the mean maximum intravesical pressure at 50.2±9.2 cmH2O and the mean intravesical pressure at 34.4±5.2 cmH2O. The maximum cystometric capacity was measured 496.8±234.4ml at conventional UDS and there was no statistical relevance between maximum cystometric capacity and post voided volume in either both urodynamic methods and blood gas parameters on the other side. The mean value of neobladder compliance was 42.7±28.5 ml/cmH2O. At the same time volumes at first, normal and maximum neobladder capacity were 244.2 ml, 351.9 ml and 496.8 ml respectively. The comparison between the mean voided volume on conventional and ambulatory UDS and also between the first one and the mean maximum voided volume on ambulatory UDS showed 406ml±210.6 vs 204.7 ml ±58. (p<0.001) and 406ml±210.6 vs 259.9 ml ±77.8 (p=0.001). Regarding maximum flow rate the values for both conventional and ambulatory UDS were 10.2ml/sec±5.2 and 8.5 ml/sec±2.8 respectively. In the same way concerning incontinence 40.6% and 56.2% of the patients experienced urine leakage during the day and 87.5% during the night on the ambulatory UDS alone. In conclusion by preserving high compliance rates, Hautmann’s orthotopic neobladder volume adaptation activity is perfect. The great value of ambulatory UDS is the exposure of daily and nocturnal incontinence episodes. This is very important, as incontinence is the major influence factor of social functioning and emotional wellbeing in these patients.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Malioris, Apostolos
- Μαλιώρης, Απόστολος
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/35665