Aristotle University Of Thessaloniki (AUTH)
Η επίδραση της αντισυμφυτικής μεμβράνης στην αποκατάσταση τραυματικών ελλειμμάτων καμπτήρων τενόντων στη ζώνη ΙΙ στο χέρι
Abstract
dc:descriptionThe effects of an anti-adhesive membrane on a cut tendon site have been adequately studied in animal models up to now. What has not been studied enough is the effect of the same membrane on a tendon deficit that is reconstructed with a tendon autograft.Purpose: The purpose of this study is to check the hypothesis that the application of an anti-adhesive membrane over a tendon autograft used to treat a zone II flexor tendon deficit in a rabbit model, will have a histologic and biomechanic influence. Methods: Thirty New Zealand rabbits were operated on. In each we created an approximately 3 cm long traumatic deficit of the deep flexor tendon of the first and fourth or the second and third fingers of its right rear leg, in zone II. The deficit was bridged with a tendon autograft, which was covered with an anti-adhesive membrane in one finger, but not in the other. Three weeks post- operatively, we operated on 23 of the animals and took 23 pairs of tendon grafts that were macroscopically and microscopically studied. On completion of six post-operative weeks, we operated on the rest animals and received 14 (7 pairs) more tendons, which were put to biomechanical testing in the Institute of Technology of AUTH.Results: In all cases we detected a foreign body type reaction around the membrane and a high presence of collagen type III at 3 weeks post-operatively. In cases with anti-adhesive membrane there was relatively less collagen type III and less macroscopic adhesions at 3weeks post-op when compared to cases without the membrane. At the same time, there was a mild to moderate increase of expression of Matrix Metalloproteinase-1(MMP1) and a mild increase of MMP2. No differentiation was observed in the expression and presence of collagen type I between cases with the membrane and cases without it. At 6 weeks post-operatively, no statistically significant difference was detected in mechanical strength (maximum load before rupture) between tendon grafts with the membrane and grafts without it (p=0,511>0,05). On the contrary, grafts coated with the anti-adhesive membrane, at six weeks, showed significantly greater flexibility (greater maximum elongation before rupture, p=0,029<0,05)Conclusions: Application of the anti-adhesive membrane (Johson-Johnson) over a tendon autograft bridging a zone II deficit in a rabbit model reduces the presence of collagen type III and macroscopic adhesions, may prosper the remodeling of extracellular matrix and increases the flexibility of the tendon graft. On the other hand, it does not affect the expression of collagen type I nor the mechanical strength of the graft itself.Clinical relevance: Every day clinical practice may be oriented with greater confidence towards the use of anti-adhesive membranes in the reconstruction of zone II flexor tendons deficits in human hand, serving the purpose of minimizing the chance of postoperative adhesions.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kapoutsis, Dimitrios
- Καπούτσης, Δημήτριος
Subjects
dc:subject × 7Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/36360