Back to search

National and Kapodistrian University of Athens

Effect of impression technique, connection type and implant angulation on accuracy of implant impressions for edentulous patients

Abstract

dc:description

Purpose: The purpose of this study was to compare the accuracy of conventional and digital impression techniques for completely edentulous patients.Materials and Methods: An edentulous mandibular cast with 5 implants was fabricated to serve as control cast at both implant and abutment-level. The 3 median implants were parallel, while the distal left had 10o and the distal right 15o angulation. For the conventional polyether impressions, a splinted and non-splinted technique was used at implant-level and abutment-level. Digital impressions were taken with an optical intraoral scanner after connecting plastic scan bodies. Standard tessellation language (STL) datasets from the 5 test groups were superimposed with STL dataset from the control cast to assess the 3-D deviations, in regards to angulation, connection type and impression technique. Accuracy of fit was was assessed with a framework on the generated casts of the test groups.Results: Significant 3-D deviations (p<0.001) were found between Group II and control. No significant difference was found between Groups I, III, IV and V compared with the control. Implant angulation up to 15o did not affect the 3-D accuracy of implant impressions (p>0.001). Conclusion: The digital implant impressions were as accurate as conventional implant impressions. The splinted implant-level technique was more accurate than non-splinted for completely edentulous patients, whereas at abutment-level there was no difference in the accuracy. Implant connection type and impression technique did affect the 3-D accuracy of implant impressions only with the non-splint technique.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Papaspyridakos, Panagiotis (Panos)
  • Παπασπυριδάκος, Παναγιώτης

Subjects

dc:subject × 10

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/36384

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Papaspyridakos, Panagiotis (Panos); Παπασπυριδάκος, Παναγιώτης. Effect of impression technique, connection type and implant angulation on accuracy of implant impressions for edentulous patients. National and Kapodistrian University of Athens, 2015. http://hdl.handle.net/10442/hedi/36384