Aristotle University Of Thessaloniki (AUTH)
Μία πρόταση για τον σχεδιασμό μονολιθικών οδογεφυρών πολλών ανοιγμάτων: αναλυτική διερεύνηση και τεκμηρίωση
Abstract
dc:descriptionThe case of a multispan, earthquake resistant bridge, with a fully integral superstructure system, is examined mainly on its enhanced seismic resistance. The main issue of the accommodation, of both the in-service and the seismic requirements of multispan integral bridge systems is addressed meticulously, with the objective of exploiting the aseismic advantages of the monolithical deck-abutments connection, but also minimizing structural and final costs. The axial tension poses a particularly adverse case, being the result of the concrete shrinkage effects and thermal changes. The demand of stresses-relief due to serviceability restraints may only be achieved through a completely controlled cracking in the superstructure, which is not prestressed, only conventionally reinforced and designed with the maximum decrease of the cross section area. The results of the current research, have been applied in a long bridge of high earthquake requirements, in the Egnatia Motorway in Greece, and the redesign of this system, resulted in important advantages concerning seismic resistance, cost effectiveness, serviceability and aesthetics. In the case of fully integral, seismically designed bridges with rigid abutments, or in long monolithical multispan bridges (viaducts, flyovers a.o.), so as to fulfil the serviceability requirements of the bridge it is very important firstly to determine precisely (a) the cracking mode of the continuous bridge deck due to thermal effects (b) the early age shrinkage and (c) the mitigative role of concrete relaxation. Each of the above requires a different approach in terms of serviceability. In this research a monolithic design is proposed which, in the opinion of the authors, without exaggerating, can be seen as one of the most holistic solutions in the field of bridge seismic design. It should be noted beforehand, that in order to make it feasible to utilize the important seismic advantages resulting from the design solution, submitted for integral cast in situ bridges, it is required to deal with the serviceability issues caused by monolithicity. The need to relieve the deck from the axial tension, occurring primarily due to the aforementioned group of causes which are responsible for the contraction of the superstructure, also necessitates the use of conventional reinforced concrete instead of prestressing, since the desired relief is achieved through cracking, for the deck to keep its length between the rigid –not movable- abutments . In this way the superstructure behaves as a continuous system, not as a frame system. Further on, the following are noted: (a) For gravity loads, the frame system mode of the monolithic superstructure (deck and piers) is altered into a continuous deck mode. (b) Concerning the seismic load combination it should be underlined that, owing to the integral connection to the abutments, the proposed totally monolithical system has the significant advantage that differential movements between the base and the pier head are absent, which means the elimination of seismic strain at the piers in the longitudinal direction. In other words, the system is not fed by the seismic amplification effect. The superstructure performs the same motion with the supports /foundations (c) Consequently, having ensured the system and especially the piers, against cracking effects, in accordance with the regulation requirements (for the crack width limitation), the aforementioned system mode, gives the greatest seismic advantage, that is the absence of seismic forces, in the longitudinal direction (d) Addressing the serviceability problems was based on the tension tie model (CEB). Rigorous research was conducted to utilize conventional reinforcing steel in bridge decks with long spans. This is due to the need for designing rigid deck-abutment and deck-pier connections, which will allow the dissipation of part of the induced seismic energy through hysteretic behavior of the abutments and the piers. Based on the aforementioned, an innovative totally monolithic bridge design became feasible by deriving six (6) new compatibility-compliance equations for the cracking control. It is desirable to underline the following as the main conclusions of the investigation: It is worth solving the difficult serviceability problems, because the resulting benefits are of great importance. More specifically the seismic resistance enhancement of the structure which in terms of safety reaches the ultimate target, is one of the aforementioned benefits. Moreover, the construction and the overall cost reduction (including maintenance and replacement costs for the technical life of the bridge) is also noticeable.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsitotas, Michael
- Τσιτώτας, Μιχαήλ
Subjects
dc:subject × 16- Πλήρως μονολιθικές γέφυρες πολλών ανοιγμάτων
- Μονολιθικές γέφυρες άνευ προέντασης με ακλόνητα ακρόβαθρα
- Αντισεισμικός σχεδιασμός μονολιθικών γεφυρών
- Πρωτότυπες εξισώσεις ελέγχου ρηγματώσεως
- Καινοτόμος όπλιση φορέα γέφυρας
- Ακρόβαθρα με μονολιθική σύνδεση με τον φορέα
- Fully integral multispan bridges
- Monolithic not poestressed superstracture
- Not movable integral abutments
- Seismic design of monolithic bridges
- Innovative compatibility - compliance equations for cracking - control
- Service ability design for totally monolithic bridges
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Engineering and Technology
- Civil Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/36456